2017
DOI: 10.1016/j.medengphy.2017.08.017
|View full text |Cite
|
Sign up to set email alerts
|

Intra- and inter-session reliability of traditional and entropy-based variables describing stance on a wobble board

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 29 publications
0
7
1
Order By: Relevance
“…Although the WB is a widely used tool in rehabilitation, the lack of quantitative data makes the evaluation of the patient's evolution difficult. To solve this problem, the system developed in this work can be used anywhere, and the generated data can easily be stored, allowing a detailed analysis of the patient's performance, such as in the device used by Bizovska et al (2017). In their work, a validation test was performed on a WB instrumented with an accelerometer capable of measuring and storing the tilt of the platform.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Although the WB is a widely used tool in rehabilitation, the lack of quantitative data makes the evaluation of the patient's evolution difficult. To solve this problem, the system developed in this work can be used anywhere, and the generated data can easily be stored, allowing a detailed analysis of the patient's performance, such as in the device used by Bizovska et al (2017). In their work, a validation test was performed on a WB instrumented with an accelerometer capable of measuring and storing the tilt of the platform.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, an instrumented WB capable of measuring the gradient vector of the MD and the displacement of the CoP during balance training could provide more assertive data for health professionals. These data can be used to develop a more effective treatment, as they allow a detailed analysis of the body response to the oscillations caused by the WB (Bizovska et al 2017). Therefore, the aim of this study was to develop and validate a supervisory system and the data acquisition based on hardware (WB) and software (control app) elements that allow the dynamic balance evaluation.…”
Section: Introductionmentioning
confidence: 99%
“…For the purpose of testing, a custom biofeedback rehabilitation tool was developed and described in detail elsewhere [ 19 ]. It consists of a wooden wobble board equipped with an inertial sensor and wireless communication with a device for displaying the progress of the rehabilitation exercise ( Figure 1 ).…”
Section: Methodsmentioning
confidence: 99%
“…These sensors measured greater mediolateral tilt variation and angular velocity in individuals with functional ankle instability during unilateral steady standing on a wobble board compared to a control group [29]. An instrumented wobble board also measured oscillations during steady standing reliably and in good agreement with force plate center of pressure fluctuations in young adults [31]; however, the validity of wobble board assessments in older adult balance remains unknown. Finally, aging and virtual visual feedback effects were measured with an instrumented wobble board during active balance training [24]; however, these IMU-based metrics were not validated.…”
Section: Introductionmentioning
confidence: 97%