2014
DOI: 10.1088/0031-9155/59/9/2265
|View full text |Cite
|
Sign up to set email alerts
|

Interventional heart wall motion analysis with cardiac C-arm CT systems

Abstract: Today, quantitative analysis of 3-D dynamics of the left ventricle (LV) cannot be performed directly in the catheter lab using a current angiographic C-arm system, which is the workhorse imaging modality for cardiac interventions. Therefore, myocardial wall analysis is completely based on the 2-D angiographic images or pre-interventional 3-D/4-D imaging. In this paper, we present a complete framework to study the ventricular wall motion in 4-D (3-D+t) directly in the catheter lab. From the acquired 2-D project… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 32 publications
0
5
0
Order By: Relevance
“…From the segmented surfaces, the blood pool volumes in end-diastole and end-systole are calculated. In addition, similar to previous work of (Müller, Maier, Zheng, Wang, Lauritsch, Schwemmer, Rohkohl, Hornegger & Fahrig 2014), a visualization of the contraction pattern is provided by color-coding the displacement of each vertex between end-systole and end-diastole and projecting the resulting mesh onto a polar map according to the 16-segment model suggested by the American Heart Association (Cerqueira et al 2002) (Fig. 2, right).…”
Section: Volumetry and Motion Visualizationmentioning
confidence: 99%
See 1 more Smart Citation
“…From the segmented surfaces, the blood pool volumes in end-diastole and end-systole are calculated. In addition, similar to previous work of (Müller, Maier, Zheng, Wang, Lauritsch, Schwemmer, Rohkohl, Hornegger & Fahrig 2014), a visualization of the contraction pattern is provided by color-coding the displacement of each vertex between end-systole and end-diastole and projecting the resulting mesh onto a polar map according to the 16-segment model suggested by the American Heart Association (Cerqueira et al 2002) (Fig. 2, right).…”
Section: Volumetry and Motion Visualizationmentioning
confidence: 99%
“…the need for a prolonged contrast injection which may be harmful for the patient. In prior work, scan protocols with acquisition durations of about 10 s and 15 s (Müller et al 2014b) were used.…”
Section: Practical Considerationsmentioning
confidence: 99%
“…A ventricle dataset (Müller et al 2013a, Maier et al 2012 of a similar design to the XCAT phantom (Segars et al 2008) was simulated. It was assumed that all materials have the same spectral absorption behaviour as water.…”
Section: Phantom Modelsmentioning
confidence: 99%
“…In the field of cardiovascular imaging, artifacts can be reduced by clustering consistent projection images using an ECG signal (Schaefer et al; 2006). Subsequently, the image may be further improved via registration in projection (Schwemmer et al; 2013) or reconstruction domain (Müller et al; 2014). Another type of motion estimation uses fiducial markers, that are identified in projection images and tracked over time (Li et al; 2006; Choi et al; 2014).…”
Section: Introductionmentioning
confidence: 99%