2015
DOI: 10.1161/circep.114.002371
|View full text |Cite
|
Sign up to set email alerts
|

Interventional Cardiac Magnetic Resonance Imaging in Electrophysiology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 22 publications
(14 citation statements)
references
References 54 publications
(55 reference statements)
0
14
0
Order By: Relevance
“…A potential application of MRI is to guide the ablation procedure in real time, which has the promise to provide acute feedback needed for successful lesion delivery . To be effective, the acute MRI methods must also predict reliably the size of the resulting chronic lesions .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A potential application of MRI is to guide the ablation procedure in real time, which has the promise to provide acute feedback needed for successful lesion delivery . To be effective, the acute MRI methods must also predict reliably the size of the resulting chronic lesions .…”
Section: Introductionmentioning
confidence: 99%
“…[6][7][8] A potential application of MRI is to guide the ablation procedure in real time, which has the promise to provide acute feedback needed for successful lesion delivery. 9,10 To be effective, the acute MRI methods must also predict reliably the size of the resulting chronic lesions. 11 LGE-MRI can partially provide such information, but due to severe restrictions on contrast administration, this contrast-enhanced imaging technique has been used only at the end of the procedure.…”
Section: Introductionmentioning
confidence: 99%
“…Real‐time MRI techniques provide an immediate and direct means of measuring ablation‐related tissue changes in addition to improved visualization of the tissue, as shown by numerous prior studies . Despite this appeal of using MRI in real time, the techniques are still being developed and are not ready for clinical use . As a result, one has to rely on indirect measurements and test for electrical isolation using functional assays.…”
Section: Discussionmentioning
confidence: 99%
“…Teams should prepare for emergency evacuation to a designated space for resuscitation with MRI-incompatible equipment. 10 Mazal et al describes the evacuation roles and reports evacuation times of less than 1 minute. 39 In-bore defibrillators 99 and temporary pacemakers are also under development to address these contingencies.…”
Section: Integration With Clinical Workflowmentioning
confidence: 99%
“…Multiple review papers have summarized clinical translation of interventional MR, 10, 11 electrophysiology applications, 10 valve and stent applications, 12 pediatric applications, 13 and technical requirements. 14, 15 …”
Section: Introductionmentioning
confidence: 99%