Intersubject Variability and Normalization Strategies for Spinal Cord Total Cross‐Sectional and Gray Matter Areas

Abstract: Background and Purpose-The quantification of spinal cord (SC) atrophy by MRI has assumed an important role in assessment of neuroinflammatory/neurodegenerative diseases and traumatic SC injury. Recent technical advances make possible the quantification of gray matter (GM) and white matter tissues in clinical settings. However, the goal of a reliable diagnostic, prognostic or predictive marker is still elusive, in part due to large inter-subject variability of SC areas. Here, we investigated the sources of this… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

17
96
7

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 37 publications
(120 citation statements)
references
References 58 publications
17
96
7
Order By: Relevance
“…To compute CSA and canal measurements analogously to previous work, the sagittal MPRAGE was resampled on the axial plane creating a packet of five contiguous slices 1‐mm thick centered at the C2‐C3 intervertebral disc 9,10 . CSA was measured semi‐automatically on these five slices and the average value computed, using the Jim “cord finder” toolkit with pre‐established settings (nominal cord diameter, 8 mm; number of shape coefficients, 24; order of longitudinal variation, 12), after manual marker placement at the cord center of each of the five slices.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…To compute CSA and canal measurements analogously to previous work, the sagittal MPRAGE was resampled on the axial plane creating a packet of five contiguous slices 1‐mm thick centered at the C2‐C3 intervertebral disc 9,10 . CSA was measured semi‐automatically on these five slices and the average value computed, using the Jim “cord finder” toolkit with pre‐established settings (nominal cord diameter, 8 mm; number of shape coefficients, 24; order of longitudinal variation, 12), after manual marker placement at the cord center of each of the five slices.…”
Section: Methodsmentioning
confidence: 99%
“…To be used for the intersubject normalizing methods, a trained operator (CA) manually measured the maximum anterior‐posterior diameter and lateral diameter of the vertebral canal on the central slice of the five‐slice packet. The product of the two diameters was computed as previously described to get the “axial_canal_product” metric 10 . V‐scale was obtained using SienaX (part of FSL) 14 …”