Interslice current change constrained B0 shim optimization for accurate high‐order dynamic shim updating with strongly reduced eddy currents

Abstract: average, by a factor of 2.1 over second-order static solutions, our proposed routine reached a factor of 2.0, while simultaneously providing a 14-fold reduction of the average maximum shim current changes. Conclusions: The proposed algorithm substantially reduces the shim amplitudes and their temporal variation, while only marginally affecting the achievable B 0 homogeneity. As a result, it has the potential to mitigate the remaining challenges in dynamic B 0 shimming and help in making its application more re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
25
0

Year Published

2019
2019
2020
2020

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 18 publications
(25 citation statements)
references
References 29 publications
(34 reference statements)
0
25
0
Order By: Relevance
“…However, resolution of the dephasing artifacts is desirable because there are several applications that can be applied to the real‐time cines that can benefit treatment including visual respiratory feedback and motion prediction. Dynamic shimming and eddy current methods are now available on commercial MRIs that may be adapted to minimizing gantry motion‐related artifacts …”
Section: Discussionmentioning
confidence: 99%
“…However, resolution of the dephasing artifacts is desirable because there are several applications that can be applied to the real‐time cines that can benefit treatment including visual respiratory feedback and motion prediction. Dynamic shimming and eddy current methods are now available on commercial MRIs that may be adapted to minimizing gantry motion‐related artifacts …”
Section: Discussionmentioning
confidence: 99%
“…Previously, it was demonstrated that nonorthogonal field profiles can compete with conventional orthogonal spherical harmonic fields for dynamic shimming purposes using a high number of shim array coils or RF coils as shim coils with dedicated hardware . Although the gradient field demands in terms of switching rates and field amplitudes are higher than in shim coils, mutual coupling might still affect the shimming performance of shim coil arrays in theory.…”
Section: Discussionmentioning
confidence: 99%
“…set. 20 The RRI power supply values and the pulse sequence were synchronized by use of an external trigger pulse from the scanner console to the RRI power supply clocked 2 ms prior to the RF excitation pulse.…”
Section: General Hardware Configurationmentioning
confidence: 99%
“…For the human brain, optimizing the B 0 shim corrections on a slice‐by‐slice (SBS) basis using dynamic shim updating (DSU) as opposed to a single global solution over the majority or the entire brain, can significantly improve homogeneity. Because of this, several groups have developed DSU approaches, including strategies for optimization and pre‐emphasis mitigation 19‐22 …”
Section: Introductionmentioning
confidence: 99%