Abstract: Objective. To evaluate NOVA View with focus on reading archived images versus microscope based manual interpretation of ANA HEp-2 slides by an experienced, certified medical technologist. Methods. 369 well defined sera from: 44 rheumatoid arthritis, 50 systemic lupus erythematosus, 35 scleroderma, 19 Sjögren's syndrome, and 10 polymyositis patients as well as 99 healthy controls were examined. In addition, 12 defined sera from the Centers for Disease Control and 100 random patient sera sent to ARUP Laboratorie… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0
1

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(15 citation statements)
references
References 25 publications
0
14
0
1
Order By: Relevance
“…Similar to the results in our study, many studies have examined agreement between automated and conventional ANA IIF analyses. Regardless of the platform on which they are based, such as EUROPattern, AKLIDES software or NOVA View, automated interpretation systems all exhibit reliable discrimination between positive and negative results [11,13,16,[21][22][23].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Similar to the results in our study, many studies have examined agreement between automated and conventional ANA IIF analyses. Regardless of the platform on which they are based, such as EUROPattern, AKLIDES software or NOVA View, automated interpretation systems all exhibit reliable discrimination between positive and negative results [11,13,16,[21][22][23].…”
Section: Discussionmentioning
confidence: 99%
“…To our knowledge, most literatures focused on reporting positive or negative rate on single devices [11,12,[26][27][28], even less data attempted to compare patterns between different assay kits [9,29]. Therefore, we further evaluated the discrepancy caused by the HEp-2 assay kits in our clinical laboratory.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The major drawback of IIF assay is that it is a labour-intensive test with multiple steps of incubation and washing, the need for a trained reader and difficult to automate. Recently, attempts to use automated systems for staining slides and reading them have been developed; they are yet to reach a wide applicability for clinical usage [20,21].…”
Section: Methodsmentioning
confidence: 99%
“…In most New Zealand (NZ) laboratories, ANA are detected by indirect immunofluorescence test (IIF) on HEp-2. However, fluorescent patterns are sometimes difficult to interpret 2,3 . Recent advances in autoimmune technologies have emerged for ANA testing, and laboratories in NZ are moving into acquiring the required knowledge and skills.…”
Section: To the Editormentioning
confidence: 99%