2011
DOI: 10.3113/fai.2011.0861
|View full text |Cite
|
Sign up to set email alerts
|

Interobserver Reliability and Intraobserver Reproducibility of Three Radiological Classification Systems for Intra-articular Calcaneal Fractures

Abstract: Clinicians should be aware of the limitation regarding the interobserver reliability and intraobserver reproducibility of the Letournel, Sanders and Zwipp classification systems for calcaneal fractures. Future studies should attempt to improve the present classification systems.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
25
0
2

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 37 publications
(31 citation statements)
references
References 46 publications
(57 reference statements)
2
25
0
2
Order By: Relevance
“…In patients in whom a secondary arthrodesis was deemed necessary, BA was measured prior to this procedure. All measurements were rounded to a full degree because of interobserver measurement reliability [20,26,29] and were made by an independent observer. A specialised trauma surgeon verified all measurements.…”
Section: Radiographic Evaluationmentioning
confidence: 99%
“…In patients in whom a secondary arthrodesis was deemed necessary, BA was measured prior to this procedure. All measurements were rounded to a full degree because of interobserver measurement reliability [20,26,29] and were made by an independent observer. A specialised trauma surgeon verified all measurements.…”
Section: Radiographic Evaluationmentioning
confidence: 99%
“…Intraarticular calcaneus fractures comprise 75% of all the calcaneus fractures. [3,4] Another important point to note is that the forces that cause the calcaneus fracture also injure the surrounding tissues to some extent.…”
mentioning
confidence: 99%
“…Das 12 fraturas analisadas, havia 8 homens (9 fraturas) e 3 mulheres, sendo 5 do lado esquerdo, 7 do direito e média de idade de 44,5 anos (31 a 59). A tabela 5 representa a avaliação da reprodutibilidade e a concordância obtida estratificando por tempo de experiência e por nível de atuação (9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19) . Com base nos dados, observa-se que os cirurgiões menos experientes, tanto do ponto de vista de tempo de atuação quanto de porcentagem de atuação, tiveram concordância intraobservador estatisticamente superior ao grupo dos mais experientes.…”
Section: Resultsunclassified