2016
DOI: 10.1134/s0040601516100086
|View full text |Cite
|
Sign up to set email alerts
|

International water and steam quality standards on thermal power plants at all-volatile treatment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
2
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…Figure reveals that such a tendency does not take place even in the case of water. For the latter compound the results of the proposed modeling framework are compared with the most recent reference data . As seen, although the current approach exhibits minor deviations from the data, this inaccuracy does not have a systematic character and should be explained by the disagreements between DIPPR’s ST expression implemented for solving the influence parameter and the reference data.…”
Section: Resultsmentioning
confidence: 96%
See 1 more Smart Citation
“…Figure reveals that such a tendency does not take place even in the case of water. For the latter compound the results of the proposed modeling framework are compared with the most recent reference data . As seen, although the current approach exhibits minor deviations from the data, this inaccuracy does not have a systematic character and should be explained by the disagreements between DIPPR’s ST expression implemented for solving the influence parameter and the reference data.…”
Section: Resultsmentioning
confidence: 96%
“…Surface tensions of pure compounds. Points, literature data. , Lines, predictions of proposed modeling framework.…”
Section: Resultsmentioning
confidence: 99%
“…The results can be considered predictive because the influence parameters for each component, c i , were not fitted to the experimental data of these mixtures. DES’s influence parameters were calculated in Section Modeling; meanwhile, water’s parameter ( c water ) is 1.0624 × 10 –20 J·m 5 ·mol –2 , which was fitted to surface tension of pure water retrieved from Petrova and Dooley . The PC-SAFT + DGT results are displayed in Figures and , and the AARDs are reported in Table S7.…”
Section: Resultsmentioning
confidence: 99%
“…Dooley. 106 The PC-SAFT + DGT results are displayed in Figures 3 and 4, and the AARDs are reported in Table S7. For each DES + water mixture, accurate results were obtained with a total average AARD and maximum average AARD of 2.28 and 2.39%, respectively.…”
Section: Industrial and Engineeringmentioning