2023
DOI: 10.1093/ejendo/lvac002
|View full text |Cite
|
Sign up to set email alerts
|

International multicenter survey on screening and confirmatory testing in primary aldosteronism

Abstract: Objective Primary aldosteronism (PA) is one of the most frequent causes of secondary hypertension. Although clinical practice guidelines recommend a diagnostic process, details of the steps remain incompletely standardized. Design and Methods In the present SCOT-PA survey, we have investigated the diversity of approaches utilized for each diagnostic step in different expert centers through a survey using Google questionnaires… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 30 publications
0
6
0
Order By: Relevance
“…Some test centres deem an ARR value greater than 50 pmol/mU as a positive screening test result; 14 an ARR beyond this threshold was identified in eleven remote ABC participants (5%), sixteen urban ABC participants (32%), and 32 TEC participants (42%) (Box 1). Other test centres define a positive screening result as an elevated ARR (> 70 pmol/mU) together with plasma aldosterone concentration greater than 270 pmol/L; 13 these criteria were met by three remote ABC participants (1%), eleven urban ABC participants (22%), and fifteen TEC participants (20%).…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Some test centres deem an ARR value greater than 50 pmol/mU as a positive screening test result; 14 an ARR beyond this threshold was identified in eleven remote ABC participants (5%), sixteen urban ABC participants (32%), and 32 TEC participants (42%) (Box 1). Other test centres define a positive screening result as an elevated ARR (> 70 pmol/mU) together with plasma aldosterone concentration greater than 270 pmol/L; 13 these criteria were met by three remote ABC participants (1%), eleven urban ABC participants (22%), and fifteen TEC participants (20%).…”
Section: Resultsmentioning
confidence: 99%
“…ARR values exceeded 70 pmol/mU in about one‐quarter of TEC and urban ABC participants, but in only six people in the remote ABC group (3%). The proportion of positive primary aldosteronism screening test results would be higher were lower ARR thresholds applied (30 or 50 pmol/mU 13‐15 ). Systolic and diastolic blood pressure levels were higher for men, and increased with waist circumference and BMI in all three study groups; systolic blood pressure increased with ARR in the TEC but not the ABC group.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…However, only in the absence of medication interference, an ARR cut-off of >70 pmol/mU has a sensitivity and specificity greater than 95% ( 26 ). There is a paucity of data to provide any robust recommendation on ARR thresholds whilst on interfering medications ( 27 29 ).…”
Section: Discussionmentioning
confidence: 99%