International comparison of AC-DC current transfer standards

Abstract: The measurements of the international comparison of ac-dc current transfer standards identified as EURAMET.EM-K12 started in June 2012 and were completed in December 2014. Twenty NMIs in the EURAMET region and one NMI in the AFRIMET region took part: BEV (Austria), CMI (Czech Republic), PTB (Germany), METAS (Switzerland), JV (Norway), UME (Turkey), GUM (Poland), IPQ (Portugal), CEM (Spain), INRIM (Italy), SP (Sweden), DANIAmet-MI-Trescal (Denmark), BIM (Bulgaria), MKEH (Hungary), SIQ (Slovenia), LNE (France), … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
2
0
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 0 publications
0
2
0
1
Order By: Relevance
“…(11) When measuring the output signal of a thermal converter based on a thermocouple with quadratic dependence [18], a similar manipulation gives an expression Δδ S =-ΔE AC /2E DC , ( 12) where E AC and E DC are the output signals of the converter S.…”
Section: Analysis Of Voltage Converter Effect On Measurement Results ...mentioning
confidence: 99%
See 1 more Smart Citation
“…(11) When measuring the output signal of a thermal converter based on a thermocouple with quadratic dependence [18], a similar manipulation gives an expression Δδ S =-ΔE AC /2E DC , ( 12) where E AC and E DC are the output signals of the converter S.…”
Section: Analysis Of Voltage Converter Effect On Measurement Results ...mentioning
confidence: 99%
“…In the available sources, it is difficult to assess whether and in what fo rm the standard uncertainty of Type A includes the scatter of the readout of the output signal of reference current thermal converter [18]- [20]. It is also unclear what the magnitude of this signal is and what the resolution of the applied DC voltage meter is .…”
Section: Discussionmentioning
confidence: 99%
“…The ac-dc current transfer difference of the CS-TC combination under calibration, δ (CS−TC) X I ac−dc , was calibrated against the ac-dc current transfer difference of the 5 A ac national current standard, δ (CS−TC) S I ac−dc , maintained at an uncertainty of 2.7 µA/A, which was validated in the framework of RMO key comparison EURAMET.EM-K12 [33].…”
Section: B Coaxial Current Shunt Calibrationmentioning
confidence: 99%
“…Los trabajos realizados en esta tesis han sido soportados por el Centro Español de Metrología (CEM) y parcialmente financiados por los programas de investigación de la Unión Europea, Q-wave [13], ACQ-PRO, [18] Trace-PQM [19], sus resultados están siendo aplicados en el proyecto DIG-AC [20].…”
Section: Caracterización De Convertidores Digitales Mediante Patrones Cuánticosunclassified