2021
DOI: 10.1016/j.engfailanal.2021.105407
|View full text |Cite
|
Sign up to set email alerts
|

Internal temperature measurement and conductor temperature calculation of XLPE power cable based on optical fiber at different radial positions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 29 publications
0
6
0
Order By: Relevance
“…To sum up, under certain conditions, the analysis of target acoustic scattering of seafloor pipeline structures will also be affected by the ocean channel environment [31]. In the visualization stage, it is necessary to introduce indicators such as sound ray correction and afternoon effect to further determine the unique attributes of the seabed target.…”
Section: Other Seabed Engineering Objectsmentioning
confidence: 99%
“…To sum up, under certain conditions, the analysis of target acoustic scattering of seafloor pipeline structures will also be affected by the ocean channel environment [31]. In the visualization stage, it is necessary to introduce indicators such as sound ray correction and afternoon effect to further determine the unique attributes of the seabed target.…”
Section: Other Seabed Engineering Objectsmentioning
confidence: 99%
“…The upper boundary is the contact surface of the soil and the top of the cable trench with the ground air, which is used as the ambient temperature to dissipate heat to the outside air region by natural convection using the convective heat transfer boundary condition as shown in Equation (7). The lower boundary is a deep layer of soil, and a constant temperature boundary condition is set as shown in Equation (8). The normal temperature gradient of the soil layer at the left and right boundaries is 0.…”
Section: Theoretical Modelmentioning
confidence: 99%
“…Therefore, this method requires the noise reduction processing of the infrared imaging to obtain accurate temperature information [6,7]. In contact temperature sensors, thermocouple sensors are often used for multi-point measurements [8,9]. Compared to infrared temperature measurement, the arrangement is flexible and allows temperature measurement at multiple locations, but it is not easy to maintain a safe electrical distance between the point sensors and equipment with high voltage levels.…”
Section: Introductionmentioning
confidence: 99%
“…On the contrary, if the operating temperature of the cable conductor is much lower than 90 °C, the operating efficiency of the cable will be reduced [ 18 ]. Therefore, conductor temperature will directly affect the aging of XLPE insulation and the operation of cable; thus, real-time cable temperature measurement is critical to the safe and steady operation of the XLPE power cable [ 19 ]. Monitoring of stress and temperature through embedded sensors is therefore mandatory.…”
Section: Introductionmentioning
confidence: 99%