Internal magnetic field measurements of translated and merged field-reversed configuration plasmas in the FAT-CM device

Abstract: Field-reversed configuration (FRC) Amplification via Translation–Collisional Merging (FAT-CM) experiments have recently commenced to study physics phenomena of colliding and merged FRC plasma states. Two independently formed FRCs are translated into the confinement region of the FAT-CM device, collided near the mid-plane of the device with a relative speed of up to ∼400 km/s, and a final merged FRC plasma state is achieved. To measure internal magnetic field profiles of the translated and merged FRC plasmas as… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
11
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(15 citation statements)
references
References 10 publications
2
11
0
Order By: Relevance
“…Magnetic measurements on the C-2 and FAT-CM device during the quiescence phase of collisional merging with theta-pinch formed FRCs [3,4,8,21] reveal having a different type of FRCs than RMF-FRCs. To give a comparison, all four models have identical B e = 0.1 T to simulate conditions of the C-2 device measurement [8].…”
Section: Comparison Of Profiles For Collisional Merging Frcmentioning
confidence: 89%
See 1 more Smart Citation
“…Magnetic measurements on the C-2 and FAT-CM device during the quiescence phase of collisional merging with theta-pinch formed FRCs [3,4,8,21] reveal having a different type of FRCs than RMF-FRCs. To give a comparison, all four models have identical B e = 0.1 T to simulate conditions of the C-2 device measurement [8].…”
Section: Comparison Of Profiles For Collisional Merging Frcmentioning
confidence: 89%
“…To determine the radial structure of field-reversed configuration (FRC) [1,2] plasmas, internal magnetic probe arrays [3][4][5][6][7][8] have been extensively used. One great importance is that integration of the B z radial profile allows direct measurement of the separatrix radius, which sets the boundary of the FRC from open field-lines.…”
Section: Introductionmentioning
confidence: 99%
“…Poloidal flux was estimated from the B z radial profile measured using the internal magnetic probe array. Poloidal flux φ p was defined as follows: where R is the radius of magnetic field neutral position (B z = 0) [9]. Under a constant external magnetic field, the poloidal flux is approximately proposed to the cross sectional area of the plasma, as expressed in Eq.…”
Section: Resultsmentioning
confidence: 99%
“…The transition of the internal magnetic field profile in the collisional merging process was experimentally observed on the FAT-CM [13]. The internal magnetic field profile was experimentally observed by an array of pickup coils installed at the midplane where the SXR detector is mounted.…”
Section: Discussionmentioning
confidence: 99%