Internal Fixation Using Clavicle Hook Plates for Distal Clavicle Fractures

Abstract: Background: To report the radiological and clinical outcomes of internal fixation using distal clavicle hook plates for distal clavicle fractures. Methods: From April 2008 to December 2012, 32 patients with distal clavicle fractures underwent surgery using an AO hook plate. The reduction was qualified and evaluated according to the radiological findings. The evaluation of the clinical outcomes was performed with the University of California at Los Angeles (UCLA) score, the Korean Shoulder score, and the visual… Show more