2009
DOI: 10.1016/j.jvs.2009.05.051
|View full text |Cite
|
Sign up to set email alerts
|

Intermediate results of a United States multicenter trial of fenestrated endograft repair for juxtarenal abdominal aortic aneurysms

Abstract: The intermediate-term (24-month) results of the 30 patients in this multicenter study are concordant with previous single-center studies and support the concept that placement of fenestrated endovascular grafts is safe and effective at centers with experience in endovascular repair and renal/mesenteric stent placement.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
216
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 310 publications
(222 citation statements)
references
References 25 publications
3
216
0
Order By: Relevance
“…Extended basic anatomic criteria and technical issues for application of FEVAR with custom-made endografts are summarized in Table 2. 39,44,[54][55][56][57][58] Despite the use of fenestrations which are necessary to incorporate visceral vessels bearing the desired sealing zone, a segment of relatively normal suprarenal aorta that constitutes the proximal neck is still required in fenestrated grafts. Most authors have developed a practice of establishing proximal landing zones in a region of > 2 cm parallel-walled and thrombus-free aorta and of minimal tortuosity.…”
Section: Anatomical Criteriamentioning
confidence: 99%
“…Extended basic anatomic criteria and technical issues for application of FEVAR with custom-made endografts are summarized in Table 2. 39,44,[54][55][56][57][58] Despite the use of fenestrations which are necessary to incorporate visceral vessels bearing the desired sealing zone, a segment of relatively normal suprarenal aorta that constitutes the proximal neck is still required in fenestrated grafts. Most authors have developed a practice of establishing proximal landing zones in a region of > 2 cm parallel-walled and thrombus-free aorta and of minimal tortuosity.…”
Section: Anatomical Criteriamentioning
confidence: 99%
“…The early and mid-term outcomes of this device have been favorable in these western countries. [5][6][7] Among Asian countries, the Cook fenestrated device is approved by the government in Taiwan, Hong Kong, China, Thailand, Malaysia, Singapore, and India at this time point. However, in Japan, it is uncertain when the device will be approved by the government because of the so-called "device lag" in the Japanese system, and the introduction of the device may be delayed significantly.…”
Section: Stent Graft Placementmentioning
confidence: 99%
“…A prospective non-randomized study evaluating the results of custom-made fenestrated Zenith stent graft in 30 patients treated at five centers was reported in 2009 [48]. There were no aneurysm-related deaths, ruptures or conversions to open repair.…”
Section: Several Reports Frommentioning
confidence: 99%