2007
DOI: 10.2106/00004623-200705000-00015
|View full text |Cite
|
Sign up to set email alerts
|

Interlocking Telescopic Rod for Patients with Osteogenesis Imperfecta

Abstract: Background: Intramedullary fixation with use of a telescopic rod with a T-piece is one of the standard methods for

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 30 publications
(11 citation statements)
references
References 20 publications
0
11
0
Order By: Relevance
“…Bone union after long bone fracture is generally favorable, and conservative treatment methods such as indirect traction and casting are used in principle during infancy and the preschool period. After the preschool period, frequent fractures and markedly poor alignment are often indications for invasive internal fixation or correction by osteotomy [7,8]. Until the age of 3 years, this patient was also conservatively treated by casting for upper limb fracture and by traction for 2-4 weeks, followed by casting, for lower limb fracture.…”
Section: Discussionmentioning
confidence: 99%
“…Bone union after long bone fracture is generally favorable, and conservative treatment methods such as indirect traction and casting are used in principle during infancy and the preschool period. After the preschool period, frequent fractures and markedly poor alignment are often indications for invasive internal fixation or correction by osteotomy [7,8]. Until the age of 3 years, this patient was also conservatively treated by casting for upper limb fracture and by traction for 2-4 weeks, followed by casting, for lower limb fracture.…”
Section: Discussionmentioning
confidence: 99%
“…Even though the results are better for elongating rods, there is a concern that the insertion of the fixed T-piece component requires exposure of the knee joint. 9 Although other techniques 10,11 have been developed to avoid arthrotomy, long-term results for these devices are not yet available. This is not a concern when nonelongating rods are used.…”
Section: Discussionmentioning
confidence: 99%
“…1,[23][24][25][26] Later in 2007, the interlocking intramedullary (IM) rod was introduced, initially for use in tibial deformities but then later expanded for use in the femur. 30 It has a single proximal entry and a distal interlocking telescopic rod. 24,30 The reported revision rates are 9% at two years and 28% at three years.…”
Section: Orthopaedic Interventionmentioning
confidence: 99%