2007
DOI: 10.1016/j.corsci.2007.05.014
|View full text |Cite
|
Sign up to set email alerts
|

Intergranular stress corrosion cracking of copper – A case study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
7
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(10 citation statements)
references
References 17 publications
1
7
0
Order By: Relevance
“…After ammonia formation the following possible reaction takes place (Todt et al, 1961;Mori et al, 2005 The enhancement of anodic current in polarization study can be explained that the corrosion on cupronickel is due to the oxidation of Cu(OH) 2. Besides, the inter granular attack is formed due to over saturation of the [Cu (NH 3 ) 4 ] 2+ ions (Kirchberg et al,2001;Mori et al, 2005 andKuznika andJunik , 2007 Formation of CuO at the metal surface is the critical step for the occurrence of stress corrosion cracking (SCC) that was noticed on XRD which supports with the observation made by Mori et al (2005).…”
Section: Atomic Force Microscopesupporting
confidence: 75%
See 1 more Smart Citation
“…After ammonia formation the following possible reaction takes place (Todt et al, 1961;Mori et al, 2005 The enhancement of anodic current in polarization study can be explained that the corrosion on cupronickel is due to the oxidation of Cu(OH) 2. Besides, the inter granular attack is formed due to over saturation of the [Cu (NH 3 ) 4 ] 2+ ions (Kirchberg et al,2001;Mori et al, 2005 andKuznika andJunik , 2007 Formation of CuO at the metal surface is the critical step for the occurrence of stress corrosion cracking (SCC) that was noticed on XRD which supports with the observation made by Mori et al (2005).…”
Section: Atomic Force Microscopesupporting
confidence: 75%
“…When the alloys stressed in tension is also exposed to a corrosive environment, the ensuring localized electrochemical dissolution of metal, combined with localized plastic deformation, opens up a crack (Agarwal et al, 2002). Protective films that form at the tip of the crack rupture, causing fresh anodic material to be exposed to the corrosive medium and SCC is propagated (Kuźnicka and Junik, 2007).…”
Section: Atomic Force Microscopementioning
confidence: 99%
“…The copper material (Cu-DHP) and the tube dimensions were in accordance with the specifications, so they were not the reason for the failure. All the other relevant failure mechanisms were also out of the question, although some of the observed features were quite similar to those of stress corrosion cracking [27][28][29][30][31]. Ant-nest corrosion occurs especially in Cu-DHP [3,6] which was the material of the heat exchanger tube in question.…”
Section: Discussionmentioning
confidence: 93%
“…In vapor test conditions, acetic acid has a higher corrosion rate than formic acid in copper tube [ 17 ]. However, in some conditions, ANC phenomena have a closeness to stress corrosion cracking and stress cracking [ 7 , 18 , 19 , 20 ].…”
Section: Introductionmentioning
confidence: 99%