2000
DOI: 10.1016/s0584-8547(00)00219-6
|View full text |Cite
|
Sign up to set email alerts
|

Interferences in the quartz tube atomizer during arsenic and antimony determination by hydride generation atomic absorption spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
8
0

Year Published

2005
2005
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(8 citation statements)
references
References 13 publications
0
8
0
Order By: Relevance
“…The effect of KI on the interferences by Bi, Se and Te on Sb signal and the interferences of Sb, As, Bi, Te, and Sn on the Se signal using oxygen and a mixture of ozone were examined by Barth et al [11]. In a study by Ay and Henden [12], a separation procedure using a GC column was applied to eliminate the inter-element interference of arsenic and antimony. In the GC column, arsine is eluted first and separated from stibine.…”
Section: Introductionmentioning
confidence: 99%
“…The effect of KI on the interferences by Bi, Se and Te on Sb signal and the interferences of Sb, As, Bi, Te, and Sn on the Se signal using oxygen and a mixture of ozone were examined by Barth et al [11]. In a study by Ay and Henden [12], a separation procedure using a GC column was applied to eliminate the inter-element interference of arsenic and antimony. In the GC column, arsine is eluted first and separated from stibine.…”
Section: Introductionmentioning
confidence: 99%
“…Nevertheless, frequent use may irrecoverably modify the surface with the consequence of a reduction in sensitivity. It has also been reported 16,17,19,20 that the original performance is not obtained by cleaning the tube. These interferences are reduced by 2 to 3 orders of magnitude by using either a hydrogen flame in QTA, 6 a miniature argon hydrogen flame, 2,21 a flame-in-gas-shield atomizer, 21 a multiple microflame QTA 22 or a long-path slot burner.…”
Section: Introductionmentioning
confidence: 98%
“…ROX is a compound that has low toxicity; however, the studies showed that its continuous usage could lead toxicity since it is transformed into i-As in chicken tissues [7,8]. The atomic techniques such as inductively coupled plasma mass spectrometry (ICP-MS) [9][10][11][12][13][14][15], hydride generation atomic absorption spectrometry (HG-AAS) [16][17][18][19][20][21] and hydride generation atomic fluorescence spectrometry (HG-AFS) [22][23][24][25] are widely used to determine arsenic in various samples. It is well known that the use of HG can improve the sensitivity and the selectivity in arsenic determination.…”
Section: Introductionmentioning
confidence: 99%