2011
DOI: 10.1021/jf104393q
|View full text |Cite
|
Sign up to set email alerts
|

Interference Prevention in Size-Exclusion Chromatographic Analysis of Debranched Starch Glucans by Aqueous System

Abstract: Branch chain-length distribution of amylopectin plays an important role on the characteristics of starch. One of the adapted protocols for determining the chain-length distribution and mass proportion of starch molecules is that starch is debranched with isoamylase and then analyzed by using high-performance size-exclusion chromatography coupled with multiangle laser-light scattering and refractive index detection (HPSEC-MALS-RI). However, ammonium sulfate in commercial isoamylase and acetate in debranching bu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(2 citation statements)
references
References 53 publications
0
2
0
Order By: Relevance
“…This in turn requires the value of the variation of refractive index with polymer concentration in the eluent, dn/dc. While a good MALLS signal is hard to obtain at low molecular weights, recent advances in MALLS detectors make this possible in systems in which the value of dn/dc is not too low, such as aqueous eluents [25] (note however that the value of dn/dc used in this reference was found with an amylodextrin of low DP obtained by degrading starch with HCl; this is a branched molecule, and because the value of dn/dc depends on the branching structure, the value is incorrect for the analyte, which is unbranched).…”
Section: Techniques and Assumptionsmentioning
confidence: 99%
“…This in turn requires the value of the variation of refractive index with polymer concentration in the eluent, dn/dc. While a good MALLS signal is hard to obtain at low molecular weights, recent advances in MALLS detectors make this possible in systems in which the value of dn/dc is not too low, such as aqueous eluents [25] (note however that the value of dn/dc used in this reference was found with an amylodextrin of low DP obtained by degrading starch with HCl; this is a branched molecule, and because the value of dn/dc depends on the branching structure, the value is incorrect for the analyte, which is unbranched).…”
Section: Techniques and Assumptionsmentioning
confidence: 99%
“…This in turn requires the value of the variation of refractive index with polymer concentration in the eluent, dn/dc. While a good MALLS signal is hard to obtain at low molecular weights, recent advances in MALLS detectors make this possible in systems in which the value of dn/dc is not too low, such as aqueous eluents [88] (note however that the value of dn/dc used in this reference was found with an amylodextrin of low DP obtained by degrading starch with HCl; this is a branched molecule, and because the value of dn/dc depends on the branching structure, the value is incorrect for the analyte, which is unbranched).…”
Section: Techniques and Assumptions For Starch Cld Experimental Analysismentioning
confidence: 99%