Interface pressure, perceptual, and mean arterial pressure responses to different blood flow restriction systems

Abstract: This study examined the cuff to limb interface pressure during blood flow restriction (BFR), and the perceptual and mean arterial pressure responses, in different BFR systems. Eighteen participants attended three experimental sessions in a randomised, crossover, counterbalanced design. Participants underwent inflations at 40% and 80% limb occlusive pressure (LOP) at rest and completed 4 sets of unilateral leg press exercise at 30% of one repetition maximum with BFR at 80% LOP. Different BFR systems were used e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
44
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 30 publications
(44 citation statements)
references
References 37 publications
(90 reference statements)
0
44
0
Order By: Relevance
“…The PT device increases cuff pressure itself in stepwise increments, analysing the pneumatic pressure pulsations in the cuff bladder by the arterial pressure pulsations at each cuff pressure increment, and uses these characteristics to determine LOP [41]. This system is comprised of a dual-purpose easyfit variable contour nylon cuff (11.5 cm x 86 cm, 5 mm thick) connected by airtight hose tubing to a PT system, and automatically regulates pressure within acceptable limits [42]. Prior to exercise the cuff was placed on the most proximal portion of the limb and LOP was calculated in the body position that the BFR stimulus would be applied [40].…”
Section: Blood Flow Restrictionmentioning
confidence: 99%
“…The PT device increases cuff pressure itself in stepwise increments, analysing the pneumatic pressure pulsations in the cuff bladder by the arterial pressure pulsations at each cuff pressure increment, and uses these characteristics to determine LOP [41]. This system is comprised of a dual-purpose easyfit variable contour nylon cuff (11.5 cm x 86 cm, 5 mm thick) connected by airtight hose tubing to a PT system, and automatically regulates pressure within acceptable limits [42]. Prior to exercise the cuff was placed on the most proximal portion of the limb and LOP was calculated in the body position that the BFR stimulus would be applied [40].…”
Section: Blood Flow Restrictionmentioning
confidence: 99%
“…A pneumatic cuff (PTS tourniquet system, Delfi medical innovations, Vancouver, Canada) (width 13.4 cm; length 58 cm) was placed around the most proximal portion of each participant's right thigh. The pneumatic system connected to the tourniquet cuff, increased the cuff pressure in stepwise increments, and when no auscultatory pulse was detected by the Doppler probe, this determined AOP 24 . The BFR pressures used during the experimental conditions were 0%, 40%, 60% and 80% of AOP in a resting condition, which matched the body position in which the intervention was carried out 18 .…”
Section: Determination Of Blood Flow Restriction Pressurementioning
confidence: 99%
“… Blood flow restriction system : different blood flow restriction systems (automatic pressure control vs. manual handheld pressure control) lead to diverging pressure on the limbs at rest and during exercise. However, one first investigation by Hughes et al [ 239 ] compared several blood flow restriction systems with different cuff widths. Therefore, the influence of blood flow restriction systems for inducing effective BFR-stimuli needs further investigations [ 239 ].…”
Section: Resistance Training With Blood Flow Restriction—an Added mentioning
confidence: 99%
“…However, one first investigation by Hughes et al [ 239 ] compared several blood flow restriction systems with different cuff widths. Therefore, the influence of blood flow restriction systems for inducing effective BFR-stimuli needs further investigations [ 239 ].…”
Section: Resistance Training With Blood Flow Restriction—an Added mentioning
confidence: 99%
See 1 more Smart Citation