Interaktion von Silikonöl mit verschiedenen Intraokularlinsen - Eine licht- und rasterelektronenmikroskopische Untersuchung

Abstract: Silicone oil is more adherent to hydrophobic IOLs than to hydrophylic IOLs. Lipoproteins of the serum play an important role in facilitating an effect of silicone oil on IOL materials. We recommend highly hydrophylic especially surface-modified IOLs for lens implantation following vitreoretinal silicone oil surgery. Implantation of silicone IOLs in vitreoretinal high risk eyes should be avoided.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
10
0
4

Year Published

1998
1998
2018
2018

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 23 publications
(14 citation statements)
references
References 9 publications
0
10
0
4
Order By: Relevance
“…Dick et al [21]had studied the interaction between silicone oil and various IOLs under light and scanning electron microscopy, using different IOL materials (PMMA, silicone, hydrogel) and surface modifications (CeeOn 809P and 809C, Soflex LI41U, Alcon AcrySof M60BM, Allergan SI-30NB, SI-40NB, Chiron adatomed 90D, C10 and C31UB, MemoryLens U940A, Corneal ISHEMA 66, Storz H60M) that were stored in vitro together with silicone oil (1,000 cs). They reported that silicone oil strongly adhered to holes and to the IOL surface, especially in the case of silicone and PMMA IOLs.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Dick et al [21]had studied the interaction between silicone oil and various IOLs under light and scanning electron microscopy, using different IOL materials (PMMA, silicone, hydrogel) and surface modifications (CeeOn 809P and 809C, Soflex LI41U, Alcon AcrySof M60BM, Allergan SI-30NB, SI-40NB, Chiron adatomed 90D, C10 and C31UB, MemoryLens U940A, Corneal ISHEMA 66, Storz H60M) that were stored in vitro together with silicone oil (1,000 cs). They reported that silicone oil strongly adhered to holes and to the IOL surface, especially in the case of silicone and PMMA IOLs.…”
Section: Discussionmentioning
confidence: 99%
“…In several clinical and experimental studies, the interaction of silicone oil with various IOLs has been investigated [19, 20, 21, 22, 23]. In most of these studies, one type of silicone oil was used.…”
Section: Introductionmentioning
confidence: 99%
“…Using a standardized preparation sequence [7], the number of vacuoles (glistenings) in the optical section was quantified using light microscopy. A third IOL was removed from its sterile packing, hydrated with BSS, and its optical surface was examined using light and scanning electron microscopy.…”
Section: Controlsmentioning
confidence: 99%
“…Furthermore, he found clear evidence that these changes were most notable and severest in patients with diabetes mellitus. The results of previous studies suggest a possible relationship between the incidence of these vacuoles and the composition of the aqueous humor [7,8]. Dick et al [7] observed an increase in intralental microvacuoles in Acrysof IOLs with the addition of silicone oil to the aqueous humor.…”
mentioning
confidence: 96%
See 1 more Smart Citation