1997
DOI: 10.1016/s0927-7757(96)03723-5
|View full text |Cite
|
Sign up to set email alerts
|

Interactions of thorium isotopes with colloidal organic matter in oceanic environments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

6
30
0

Year Published

2004
2004
2019
2019

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 66 publications
(36 citation statements)
references
References 36 publications
6
30
0
Order By: Relevance
“…Total recovery rate was 98% for the carbon and 90% for 234 Th, which lie within the range found in other studies (Dai and Benitez-Nelson, 2001;Guo et al, 1997). The directly measured colloidal fraction was quite small for both OC (6% of the b 0.2 Am fraction) and 234 Th (5% of the b 0.2 Am fraction), which lies within the lower end of the range found in other studies (Dai and BenitezNelson, 2001;Guo et al, 1997). The ultrafiltered fraction contributed 88% and 42% OC and 234 Th, respectively to the dissolved (b 0.2 Am) fraction.…”
Section: Methodological Concerns: Mass Balance For Ultrafiltrationsupporting
confidence: 89%
See 2 more Smart Citations
“…Total recovery rate was 98% for the carbon and 90% for 234 Th, which lie within the range found in other studies (Dai and Benitez-Nelson, 2001;Guo et al, 1997). The directly measured colloidal fraction was quite small for both OC (6% of the b 0.2 Am fraction) and 234 Th (5% of the b 0.2 Am fraction), which lies within the lower end of the range found in other studies (Dai and BenitezNelson, 2001;Guo et al, 1997). The ultrafiltered fraction contributed 88% and 42% OC and 234 Th, respectively to the dissolved (b 0.2 Am) fraction.…”
Section: Methodological Concerns: Mass Balance For Ultrafiltrationsupporting
confidence: 89%
“…Colloidal matter using both cut-offs are included in the average values as there was no significant difference in the fractionation whether a 10 or 3 kDa filter membrane was used. Total recovery rate was 98% for the carbon and 90% for 234 Th, which lie within the range found in other studies (Dai and Benitez-Nelson, 2001;Guo et al, 1997). The directly measured colloidal fraction was quite small for both OC (6% of the b 0.2 Am fraction) and 234 Th (5% of the b 0.2 Am fraction), which lies within the lower end of the range found in other studies (Dai and BenitezNelson, 2001;Guo et al, 1997).…”
Section: Methodological Concerns: Mass Balance For Ultrafiltrationsupporting
confidence: 88%
See 1 more Smart Citation
“…The ratios in this very small sub-micron size range seemed to fit a pattern of decreasing C / 234 Th with particle size (Burd et al, 2000;Guo et al, 1997Guo et al, , 2002a. A model that included uptake of Th by small and abundant colloids and production of larger aggregates using a particle aggregation model, predicted a decrease in C / 234 Th with size for the smallest size classes and relatively invariant or slowly decreasing C / 234 Th in the 1-100 Am range (Burd et al, 2000).…”
Section: Overview Of Processes Controlling the C / 234 Th Ratio Of Mamentioning
confidence: 86%
“…Other data sets followed that measured C / 234 Th in colloidal size classes using cross flow filtration (e.g., Moran and Buesseler, 1992;Guo et al, 1997;replotted in Santschi et al, 2006-this volume) or small volume filtration for the smaller particle size classes. The ratios in this very small sub-micron size range seemed to fit a pattern of decreasing C / 234 Th with particle size (Burd et al, 2000;Guo et al, 1997Guo et al, , 2002a.…”
Section: Overview Of Processes Controlling the C / 234 Th Ratio Of Mamentioning
confidence: 99%