“…Equivalent circuit of a wound rotor induction machine is also provided in Figure 1. [11,12] R sa , R sb , R sc are the winding resistances of the stator phases a, b and c, R ra R rb R rc are the winding resistances of the rotor phases a, b and c, L sa , L sb, L sc are the selfinductances of the stator phases a, b and c, L ra, L rb, L rc are the self-inductances of the rotor phases a, b and c. L s(x,y) are the stator mutual inductances between phases for x= a, b and c , y= a, b and c and x y. L r(x,y) are the rotor mutual inductances between phases for x= a, b and c , y= a, b and c and x y. i sa , i sb , i sc are the stator current of the phases a, b and c, i ra , i rb , i rc are the rotor current of the phases a, b and c, v sa , v sb , v sc are the stator voltage of the phases a, b and c, emf sa , emf sb , emf s are the electromotive forces on the stator side for the phases a, b and c, emf ra , emf rb , emf rc are the electromotive forces on the rotor side for the phases a, b and c respectively.…”