2015
DOI: 10.1016/j.euprot.2015.06.001
|View full text |Cite
|
Sign up to set email alerts
|

Inter-laboratory evaluation of instrument platforms and experimental workflows for quantitative accuracy and reproducibility assessment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
51
0
1

Year Published

2016
2016
2020
2020

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 34 publications
(55 citation statements)
references
References 21 publications
3
51
0
1
Order By: Relevance
“…20 fmol/ μ L to 200 pmol/ μ L (see Table ). All of these proteins are part of the PeptiQuant Workflow Performance Kit (MRM Proteomics, catalogue number WFPK‐A6495‐1) used to monitor LC/MRM–MS performance . For each protein, one proteotypic surrogate peptide was chosen.…”
Section: Methodsmentioning
confidence: 99%
“…20 fmol/ μ L to 200 pmol/ μ L (see Table ). All of these proteins are part of the PeptiQuant Workflow Performance Kit (MRM Proteomics, catalogue number WFPK‐A6495‐1) used to monitor LC/MRM–MS performance . For each protein, one proteotypic surrogate peptide was chosen.…”
Section: Methodsmentioning
confidence: 99%
“…While this variability may satisfy the guidelines for Tier 1 and 2 assays, it is unsuitable for clinical practice. For some methods, large-scale analyses of quantitative proteomic assays have been performed across independent laboratories using a diverse set of LC-MS platforms [64,[112][113][114][115]. These studies have collectively demonstrated the feasibility in measuring a broad range of plasma proteins (encompassing high-to-low abundance) using standardized practices for system suitability, quality control, and quantitative analysis.…”
Section: Expert Commentarymentioning
confidence: 99%
“…With the recent advances in SRM technology, front‐end sample preparation, and bioinformatics tools (e.g., Skyline , QuaSAR , and Qualis‐SIS ), SRM‐based targeted proteomics technique is nearly mature for routinely reliable quantification of 10–100 s of target proteins in complex biological samples . In recent years studies for systematic evaluation of SRM assays and their performance have been conducted, such as developing a system suitability protocol for quantitative assessment of intra‐ and inter‐laboratory instrument performance in LC‐SRM analysis , large‐scale development of standardized SRM assays , inter‐laboratory evaluation of SISCAPA‐SRM , and defining three tiers of SRM assays using a “fit‐for‐purpose” approach . In 2012 targeted proteomics was selected as Method of the Year in Nature Methods .…”
Section: Recent Advances In Srm Sensitivity and Its Applicationmentioning
confidence: 99%