2012
DOI: 10.1080/07373937.2012.675533
|View full text |Cite
|
Sign up to set email alerts
|

Intensification of Low-Temperature Drying by Using Ultrasound

Abstract: 28Low temperature air drying involves temperatures below or close to the freezing point 29 and aims to reduce the water content or to remove organic solvents keeping quality 30 attributes, thus it has a great potential in food, chemical, pharmaceutical and cosmetic 31 industries. Depending on the temperature and solvent involved, the removal is by 32 evaporation or sublimation, but in all cases, the drying process is slow due to the low 33 temperature used. An efficient ultrasound application at atmospheric pr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
63
0
1

Year Published

2012
2012
2024
2024

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 87 publications
(71 citation statements)
references
References 25 publications
3
63
0
1
Order By: Relevance
“…Drying experiments were carried out in a convective drier with air recirculation ( Figure 1), already described in the literature [20]. The system provides automatic air velocity and temperature control and an drying chamber excited by an ultrasonic transducer.…”
Section: Drying Experimentsmentioning
confidence: 99%
See 1 more Smart Citation
“…Drying experiments were carried out in a convective drier with air recirculation ( Figure 1), already described in the literature [20]. The system provides automatic air velocity and temperature control and an drying chamber excited by an ultrasonic transducer.…”
Section: Drying Experimentsmentioning
confidence: 99%
“…During the AFD (-6ºC) of peas, Bantle and Eikevik [19] reported an increase of 14.6% in the diffusion coefficient linked to US application. Meanwhile, Garcia-Perez et al [20] achieved an increase in effective diffusivity of around 400% during the drying of apples, carrot and eggplants at -14ºC. The ultrasonic performance variable found in the literature for LTD applications could be linked to the efficiency of the transducer used, and so to the different ultrasonic power applied.…”
Section: Introductionmentioning
confidence: 96%
“…This fact could be explained considering that in the AFD experiments the internal resistance to mass transfer was much higher than the external one, which was nearly negligible. In the case of USAFD experiments, US diminished the internal resistance to mass transfer, which leads to a more significant external resistance [8]. This fact explains also the low %VAR provided by the diffusion model in the USAFD experiments.…”
Section: Drying Kineticsmentioning
confidence: 66%
“…Atmospheric freeze drying experiments were conducted in a convective drier with air recirculation, temperature and air velocity control and an ultrasonically activated drying chamber, already described in literature [8]. Kinetics were carried out at constant air velocity (2 ms-1), temperature (-10ºC) and relative humidity of the air (10%) with (20.5 kWm-3, USAFD) and without ultrasonic application (AFD).…”
Section: Drying Experimentsmentioning
confidence: 99%
“…Previous research like (Rodríguez et al, 2010;Riera et al, 2015) shows that these HPU technologies provide good performance in processes like defoaming, particle agglomeration or ultrasonic cleaning, among others. In the particular case of food dehydration at low temperature, it has been proved by (Garcia-Perez et al, 2012) that HPU provides a faster and more economic performance, that also improves the quality of the final product.…”
Section: Introductionmentioning
confidence: 99%