2020
DOI: 10.1016/j.compbiomed.2020.103732
|View full text |Cite
|
Sign up to set email alerts
|

Intelligent analysis of coronal alignment in lower limbs based on radiographic image with convolutional neural network

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 25 publications
(25 citation statements)
references
References 25 publications
0
19
1
Order By: Relevance
“…Nguyen et al reported that the MAE for mLDFA was 0.899° for the right limbs and 1.137°f or the left limbs. In our study, the predicted MAE for MPTA of the right and left limbs was 0.638° and 0.602°, respectively, which are also better than the ones reported by Nguyen et al [19] (the MAE for MPTA of right and left limbs was 1.146° and 1.032°, respectively). Additionally, Zheng et al [20] realized the mechanical axis of the lower limbs using the AI model with an MAE of 4.5 mm, and our corresponding MAE values for the right and left legs were 1.124 mm and 1.032 mm, respectively.…”
Section: Discussioncontrasting
confidence: 65%
“…Nguyen et al reported that the MAE for mLDFA was 0.899° for the right limbs and 1.137°f or the left limbs. In our study, the predicted MAE for MPTA of the right and left limbs was 0.638° and 0.602°, respectively, which are also better than the ones reported by Nguyen et al [19] (the MAE for MPTA of right and left limbs was 1.146° and 1.032°, respectively). Additionally, Zheng et al [20] realized the mechanical axis of the lower limbs using the AI model with an MAE of 4.5 mm, and our corresponding MAE values for the right and left legs were 1.124 mm and 1.032 mm, respectively.…”
Section: Discussioncontrasting
confidence: 65%
“…Specifically, the MAE of the predicted mLDFA was 0.642° for the right limbs and 0.656° for the left limbs, and the errors were much lower, similar to a previous report. Nguyen et al [ 20 ] reported that the MAE for mLDFA was 0.899° for the right limbs and 1.137° for the left limbs. In our study, the predicted MAE for MPTA of the right and left limbs was 0.638° and 0.602°, respectively, which are also better than the ones reported by Nguyen et al [ 20 ] (the MAE for MPTA of right and left limbs was 1.146° and 1.032°, respectively).…”
Section: Discussionmentioning
confidence: 99%
“…Nguyen et al [ 20 ] reported that the MAE for mLDFA was 0.899° for the right limbs and 1.137° for the left limbs. In our study, the predicted MAE for MPTA of the right and left limbs was 0.638° and 0.602°, respectively, which are also better than the ones reported by Nguyen et al [ 20 ] (the MAE for MPTA of right and left limbs was 1.146° and 1.032°, respectively). Additionally, Zheng et al [ 21 ] determined the mechanical axis of the lower limbs using the AI model with an MAE of 4.5 mm, and our corresponding MAE values for the right and left legs were 1.124 mm and 1.032 mm, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, we used a decentralized CNN model [17][18][19] previously proposed as a highaccuracy landmark detecting method for medical images. The advantage of this method is that it narrows the ROI after each order, which not only reduces the number of non-related features that can affect the results, but also increases the diversity of the training dataset.…”
Section: Decentralized Cnn To Evaluate Anterior Incisor Inclinationmentioning
confidence: 99%