1988
DOI: 10.1107/s0021889888005400
|View full text |Cite
|
Sign up to set email alerts
|

Integration of single-crystal reflections using area multidetectors

Abstract: The development of multidetectors for use in X‐ray and neutron scattering experiments has created an interest in methods for integrating Bragg peaks in three‐dimensional data arrays representing intensity scattered from single crystals. A method of using a priori information, extracted from the strongest peaks, to obtain statistically optimum results has been developed at the Institut Laue–Langevin (ILL), Grenoble. The method is outlined in this paper and results of its application to neutron diffraction are d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
202
0

Year Published

1996
1996
2017
2017

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 226 publications
(202 citation statements)
references
References 5 publications
0
202
0
Order By: Relevance
“…A twodimensional 80 × 80 mm 2 area detector was used for all measurements [28]. An asymmetric cryomagnet with vertical opening of +20 • and −5 • supplying a magnetic field of up to 60 kOe was used throughout the experiment.…”
Section: Methodsmentioning
confidence: 99%
“…A twodimensional 80 × 80 mm 2 area detector was used for all measurements [28]. An asymmetric cryomagnet with vertical opening of +20 • and −5 • supplying a magnetic field of up to 60 kOe was used throughout the experiment.…”
Section: Methodsmentioning
confidence: 99%
“…The crystal was rotated 20° between patterns, which were recorded in exposures of 90 minutes. The patterns were indexed using the program LAUEGEN 63,64 and the reflections integrated using the local program INTEGRATE+ 65 and normalised to a common incident wavelength using the program rearrange. Correction for absorption was deemed unnecessary in view of the small sample volume.…”
Section: Neutron Single-crystal Diffractionmentioning
confidence: 99%
“…The cell dimensions were refined using the ILL program RAFD9 and integrated intensities produced using the ILL program RACER. 35 The data were corrected for absorption in the crystal using the program DATAP. 36 Crystal structure refinements of the reduced squared structure factors (F 2 ) were performed using the program FULLPROF.…”
Section: Single Crystal Structure At 16 K From Neutron Diffractionmentioning
confidence: 99%