Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging

Abstract: For three-dimensional (3D) ultrasound imaging, connecting elements of a two-dimensional (2D) transducer array to the imaging system's front-end electronics is a challenge because of the large number of array elements and the small element size. To compactly connect the transducer array with electronics, we flip-chip bond a 2D 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array to a custom-designed integrated circuit (IC). Through-wafer interconnects are used to connect the CMUT elements… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
146
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 201 publications
(154 citation statements)
references
References 40 publications
1
146
0
Order By: Relevance
“…Using (5) and the energies in table I and II the power consumption P T,Nj [mW] as a function of the period, T [µs], and the number of transitions per period, N j , is shown in (6) and (7) for the single-ended and differential output stages respectively. Using these equations, the power consumption of any pulse shape can be found for both topologies.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Using (5) and the energies in table I and II the power consumption P T,Nj [mW] as a function of the period, T [µs], and the number of transitions per period, N j , is shown in (6) and (7) for the single-ended and differential output stages respectively. Using these equations, the power consumption of any pulse shape can be found for both topologies.…”
Section: Resultsmentioning
confidence: 99%
“…2. As it can be seen, three voltage levels correspond to six different voltage transitions, tr j (j ∈ [1,6]). From now on any pulse shape is characterized by its total period, T , and the number of each tr j transitions, N j .…”
Section: A Power Consumption Expressionmentioning
confidence: 99%
“…However, improvement in MEMS technologies enables us to make very small micro-machined ultrasonic sensors. One of them is capacitive micro-machined ultrasonic transducer (CMUT) (3) . CMUT enables the frontend to be small with integrated circuits(IC) and many receive elements can be placed.…”
Section: Introductionmentioning
confidence: 99%
“…These CMUTs are replacing the long-established piezoelectric transducers in high frequency and high resolution ultrasound imaging due to their attractive features of micro-fabrication, wide bandwidth, very high level of integration, and batch fabrication [4][5][6]. CMUTs can easily be integrated with CMOS front-end electronics either through flip-chip bonding [7][8][9] or monolithically through CMUTs on the CMOS process [2,3,10,11]. The integration of CMOS electronic circuits with CMUTs will greatly cut down the cost of ultrasound imaging systems as the mass production of CMOS electronic integrated circuits is very cheap.…”
Section: Introductionmentioning
confidence: 99%
“…Such integration of CMUTs with CMOS front-end electronics fits best with the requirements of IVUS imaging system probes. All these best features of CMUTs along with low-cost high-performance CMOS interface electronic circuits enable us to make a very cost effective integrated ultrasound system [2][3][4][5][6][7][8][9][10][11].…”
Section: Introductionmentioning