2013
DOI: 10.1063/1.4795828
|View full text |Cite
|
Sign up to set email alerts
|

Integrated multichannel photon timing instrument with very short dead time and high throughput

Abstract: Precisely timed detection of single photons plays an important role in the field of quantum information processing and fluorescence sensing. The method of time-correlated single photon counting is therefore constantly evolving and the associated instrumentation is being improved with new ideas and technologies. Simultaneous, time tagged readout of multiple detector channels is invaluable in many applications, spanning from fluorescence lifetime imaging in biology to the measurement of quantum optical correlati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
16
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 40 publications
(17 citation statements)
references
References 31 publications
0
16
0
Order By: Relevance
“…Commercial TCSPC systems usually have optimal count rates from SPADs or photomultipler tubes (PMTs), but they are mostly single channel systems. Recently 8 channel [40] and 16 channel [41] TCSPC systems have been introduced. In the case of 16 channel system [41] the channels are not truly independent at high count rates due to the high probability of co-incidence or cross-talk.…”
Section: Introductionmentioning
confidence: 99%
“…Commercial TCSPC systems usually have optimal count rates from SPADs or photomultipler tubes (PMTs), but they are mostly single channel systems. Recently 8 channel [40] and 16 channel [41] TCSPC systems have been introduced. In the case of 16 channel system [41] the channels are not truly independent at high count rates due to the high probability of co-incidence or cross-talk.…”
Section: Introductionmentioning
confidence: 99%
“…In all those cases, the time measurement electronics must be duplicated or, at least, smart signal routing must be employed to minimize size and cost of electronics. 12,13 In this paper, we present a stand-alone TDC Card able to measure time intervals up to 10 μs with a constant 10 ps resolution, 21 ps single-shot precision, and 1.25% LSB rms (i.e., 0.125 ps), DNL. The compact dimensions and the multifunction I/O edge-card connector allow easy integration of the Card into multichannel timing measurement systems or in other complex systems requiring precise time measurement.…”
Section: Introductionmentioning
confidence: 99%
“…If an accurate lifetime measurement requires 100 or more photons, the maximum pixel rate for a FLIM image is already reduced to ~10 kHz resulting in an acquisition time of more than 1.5 minutes for a 1024 × 1024 pixel image. Highly sophisticated counting modules from companies like PicoQuant or Becker & Hickl can extend the count rates of TCSPC systems up-to 40 Mcounts/s using fastest counting electronics [9]. However, this increase in speed comes with a loss in accuracy of the lifetime measurement because of pile-up effects [10].…”
Section: Introductionmentioning
confidence: 99%