2024
DOI: 10.35833/mpce.2022.000717
|View full text |Cite
|
Sign up to set email alerts
|

Integrated Frequency-constrained Scheduling Considering Coordination of Frequency Regulation Capabilities from Multi-source Converters

Jiaming Li,
Ying Qiao,
Zongxiang Lu
et al.

Abstract: As the proportion of renewable energy (RE) increases, the inertia and the primary frequency regulation (FR) capability of the power system decrease. Thus, ensuring frequency security in the scheduling model has become a new technical requirement in power systems with a high share of RE. Due to a shortage of conventional synchronous generators, the frequency support of multi-source converters has become an indispensable part of the system frequency resources, especially variable-speed wind turbine generation (W… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2
1
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(1 citation statement)
references
References 47 publications
0
1
0
Order By: Relevance
“…However, this approach is highly conservative. The authors of [15] proposed improved iteration-based strategies that allow the nonlinear constraints on frequency security to be linearized exactly. All the above literature only addresses the reconstruction of the frequency security constraints without accounting for the governor limit or when the governor limit is known, and it is important to show that the frequency security constraints of the system will be more complex when the limiting link is taken into account, and representing the constraints in a linearized manner will impose a greater computational burden.…”
Section: Introductionmentioning
confidence: 99%
“…However, this approach is highly conservative. The authors of [15] proposed improved iteration-based strategies that allow the nonlinear constraints on frequency security to be linearized exactly. All the above literature only addresses the reconstruction of the frequency security constraints without accounting for the governor limit or when the governor limit is known, and it is important to show that the frequency security constraints of the system will be more complex when the limiting link is taken into account, and representing the constraints in a linearized manner will impose a greater computational burden.…”
Section: Introductionmentioning
confidence: 99%