2011
DOI: 10.1002/eej.21058
|View full text |Cite
|
Sign up to set email alerts
|

Insulation technology in dry air and vacuum for a 72‐kV low‐pressure dry‐air insulated switchgear

Abstract: SUMMARYA new 72-kV rated low-pressure dry-air insulated switchgear applying electromagnetic actuation and a function that supports CBM has been developed. First, the dielectric characteristics in dry air under lightning impulse application were investigated for bare and insulator-covered electrodes. The dependence of the breakdown electric field strength on the effective area was found in order to apply it to the configuration design of the insulation mold for the vacuum interrupter. In addition, the dependenc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
11
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(11 citation statements)
references
References 5 publications
(1 reference statement)
0
11
0
Order By: Relevance
“…3,4 Air-insulated switchgear cabinet is a closed equipment integrated by circuit breaker, isolating switch load switch, mutual inductor and other protection device. 5 Due to the closed structure, the insulation defect-induced damage can be more serious than that in the open-type equipment once the discharge occurs.…”
Section: Introductionmentioning
confidence: 99%
“…3,4 Air-insulated switchgear cabinet is a closed equipment integrated by circuit breaker, isolating switch load switch, mutual inductor and other protection device. 5 Due to the closed structure, the insulation defect-induced damage can be more serious than that in the open-type equipment once the discharge occurs.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, this gaseous insulation medium was classified as a greenhouse gas at the Kyoto protocol climate conference in 1997, which has limited its use. In order to find a SF 6 substitute, researchers have examined SF 6 mixture gases [1][2][3], N 2 , N 2 /O 2 mixture gas, dry air [4,5], and CO 2 gas [6,7] for alternative insulation gases. Alternative gases, however, have a problem in insulation performance compared to SF 6 .…”
Section: Introductionmentioning
confidence: 99%
“…Studies [17][18][19][20][21] presented the surface discharge characteristics and their mechanisms in compressed gases, vacuum and air. On the other hand, it was relatively insufficient to examine the evaluation of the surface insulation performance and the surface discharge characteristics in eco gases such as N 2 , N 2 /O 2 mixture gas, and dry air [4,5,22]. Recently, Sato et al [23] developed a solid insulated switchgear (SIS) in which an epoxy casting material was used for solid insulation.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations