Insulation condition diagnosis of oil-immersed paper insulation based on non-linear frequency-domain dielectric response

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
19
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 47 publications
(20 citation statements)
references
References 19 publications
0
19
0
Order By: Relevance
“…In Figure 12 , the test results at different voltages with the same wiring method are caused by the blocking effect of cellulose on ion movement [ 19 ]. With different wiring methods, the difference of tan δ - f is mainly caused by the macroscopic space charge polarization.…”
Section: Discussionmentioning
confidence: 99%
“…In Figure 12 , the test results at different voltages with the same wiring method are caused by the blocking effect of cellulose on ion movement [ 19 ]. With different wiring methods, the difference of tan δ - f is mainly caused by the macroscopic space charge polarization.…”
Section: Discussionmentioning
confidence: 99%
“…Review existing investigation, the approaches for oil-immersed insulating condition prediction based on dielectric response spectroscopy can be divide into two types. One is based on extracting the feature parameters from the dielectric response curves [ 11 , 15 , 16 , 17 ]. The other is realized by establishing the equivalent circuit model to extract the feature parameters of dielectric response property [ 18 , 19 ].…”
Section: Introductionmentioning
confidence: 99%
“…The most commonly used state, in electrical engineering, is the solid one. An ideal dielectric material is a medium that does not contain any free electric charges which can move from molecule to molecule [1][2][3]. It is sometimes called electrical insulation.…”
Section: Introductionmentioning
confidence: 99%
“…Dependence, on both temperature and frequency, of both the dielectric constant (DK) and the dissipation factor (DF) has been already reported in many research papers [1,[6][7][8][9][10][11][12][13]. However, DK and DF in datasheets are average values (typical values).…”
Section: Introductionmentioning