Abstract:Coil specimens were prepared by continuous coating on a copper wire with flexible PAI (polyamideimide) and PAI/nanosilica (5 wt%) varnish and thermally aged at 150, 200 and 250℃ for 5, 10 and 15 days, respectively. AC insulation breakdown voltage was investigated under inverter surge condition at 60 Hz and 1,000 Hz and insulation breakdown voltage decreased with increasing aging temperature and aging time at each 60 and 1,000 Hz.
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.