“…A partial section (650-1900 cm À1 ) of the GC-sIR spectra recorded for LSD, MIPLA, and LAMPA is shown in Figure 8 to allow for a spectral comparison (full spectra and overlaid spectra are supplied as Supporting Information). The spectrum of LSD was consistent with others reported in the literature (e.g., Mills et al 27 ) including signals typical for other lysergamides at 1627 (C=O str ), 1448 (C-N str ), and 779 and 749 cm À1 that might have been associated with C-H out of plane deformation vibrations in the indole part of the molecule. 67 A visual inspection of all three spectra in Figure 8 revealed distinct differences.…”
Section: Spectroscopic Featuressupporting
confidence: 90%
See 3 more Smart Citations
“…A partial section (650-1900 cm À1 ) of the GC-sIR spectra recorded for LSD, MIPLA, and LAMPA is shown in Figure 8 to allow for a spectral comparison (full spectra and overlaid spectra are supplied as Supporting Information). The spectrum of LSD was consistent with others reported in the literature (e.g., Mills et al 27 ) including signals typical for other lysergamides at 1627 (C=O str ), 1448 (C-N str ), and 779 and 749 cm À1 that might have been associated with C-H out of plane deformation vibrations in the indole part of the molecule. 67 A visual inspection of all three spectra in Figure 8 revealed distinct differences.…”
Section: Spectroscopic Featuressupporting
confidence: 90%
“…It is recommended to consider increasing the scan range to capture this ion. Recorded (or displayed) scan ranges reported for LAMPA spectra previously included m/z 150-350, 7 m/z 50-330, 19 m/z 50-330, 20 m/z 40-340, 8 m/z 25-400, 22 m/z 40-360, 15 m/z 20-336,, 24 m/z 40-330, 27 and m/z 29-600. 25 As suggested previously by other authors, inclusion of lower masses into the scan range requires particular attention to cleanliness of the instrumentation to minimize appearance of low mass impurities.…”
Section: Gc-msmentioning
confidence: 99%
See 2 more Smart Citations
“…The brands used (A: Innovator product, B: Generic product-Indian origin, and C: Generic product Indian origin) [7][8][9][10].…”
mentioning
confidence: 99%