Abstract: Rationale and Objectives We aimed to evaluate whether implementation of a low-dose CT-guided lung biopsy protocol, with the support of individual radiologists in the section, would lead to immediate and sustained decreases in radiation dose associated with CT-guided lung biopsies. Materials and Methods A low-dose CT-guided lung biopsy protocol was developed with modifications of kilovoltage peak (kVp), milliamperes (mA), and scan coverage. 413 CT guided lung biopsies were evaluated over a three-year period b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
12
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(16 citation statements)
references
References 16 publications
3
12
1
Order By: Relevance
“…In our study, we adjusted the tube current to 10% of the normal current and achieved a more than 90% reduction in radiation exposure. This reduction extent was largely consistent with that (53%-95%) in past investigations regarding low-dose CT-guided lung biopsy [12,23,24]. Although major dose reductions exacerbated noise and decreased image quality, low-dose CT at 120 kV and 15 mA/s allowed for an image quality adequate for CNB procedure.…”
Section: Discussionsupporting
confidence: 88%
See 1 more Smart Citation
“…In our study, we adjusted the tube current to 10% of the normal current and achieved a more than 90% reduction in radiation exposure. This reduction extent was largely consistent with that (53%-95%) in past investigations regarding low-dose CT-guided lung biopsy [12,23,24]. Although major dose reductions exacerbated noise and decreased image quality, low-dose CT at 120 kV and 15 mA/s allowed for an image quality adequate for CNB procedure.…”
Section: Discussionsupporting
confidence: 88%
“…The low-dose CT protocol could be achieved by reducing the tube voltage and/or current [12,23,24]. In our study, we adjusted the tube current to 10% of the normal current and achieved a more than 90% reduction in radiation exposure.…”
Section: Discussionmentioning
confidence: 94%
“…Repetitive helical acquisitions remain mandatory to identify the anatomically safest path because they allow a retrospective analysis of the 3D volume that can identify vascular structures and organs to avoid (1). Considering the recent awareness of the cancer-inducing risks of radiation, dose optimization is currently an important issue (2)(3)(4)(5)(6)(7)(8)(9)(10). Regarding helical acquisitions, international practice guidelines for optimization recommend limiting their number and length (1,(11)(12)(13) and preferring sequential or fluoroscopic acquisitions when possible (3,7,10).…”
Section: Introductionmentioning
confidence: 99%
“…Considering the recent awareness of the cancer-inducing risks of radiation, dose optimization is currently an important issue (2)(3)(4)(5)(6)(7)(8)(9)(10). Regarding helical acquisitions, international practice guidelines for optimization recommend limiting their number and length (1,(11)(12)(13) and preferring sequential or fluoroscopic acquisitions when possible (3,7,10).…”
Section: Introductionmentioning
confidence: 99%
“…[ 3 5 ] However, in most previous studies regarding of low-dose CT-guided lung biopsy, they included both lung masses and lung nodules. [ 3 , 4 ] The multiple disease types usually caused the potential bias. A study which focuses on unique disease type is required.…”
Section: Introductionmentioning
confidence: 99%