Instantaneous Power Quality Indices Based on Single-Sideband Modulation and Wavelet Packet-Hilbert Transform

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
41
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 45 publications
(41 citation statements)
references
References 21 publications
0
41
0
Order By: Relevance
“…The proposed methodology for phasor estimation is depicted in Figure 1. The first stage consists of the estimation of both the fundamental component phasor and its frequency, where the amplitude and phase are computed by means of the analytic signal (x(t) r + ix(t) i [27]) obtained through the proposed complex FIR filter. This filter is designed from the frequency response of a reference band-pass filter as shown in Figure 2a.…”
Section: Proposed Methodologymentioning
confidence: 99%
See 2 more Smart Citations
“…The proposed methodology for phasor estimation is depicted in Figure 1. The first stage consists of the estimation of both the fundamental component phasor and its frequency, where the amplitude and phase are computed by means of the analytic signal (x(t) r + ix(t) i [27]) obtained through the proposed complex FIR filter. This filter is designed from the frequency response of a reference band-pass filter as shown in Figure 2a.…”
Section: Proposed Methodologymentioning
confidence: 99%
“…SSB modulation is an efficient amplitude modulation technique commonly used in radio communications. Yet, this technique is also employed in signal processing, whose purpose is to shift frequency components using a carrier frequency [26,27]. This modulation is based on an analytic signal.…”
Section: Single Sideband Modulationmentioning
confidence: 99%
See 1 more Smart Citation
“…It is worth noticing that the HT has been previously applied to the analysis of power signals, because of the capability to extract an instantaneous envelope of the signal under analysis [21]. This peculiar property is typically employed, in combination with singular value decomposition [22] or wavelet transform [23], for a nearly real-time monitoring of power quality indices. In [24], HT is applied to the autocorrelation of the acquired power signal to design an innovative P-class PMU for protection applications.…”
Section: Introductionmentioning
confidence: 99%
“…Although many efforts have been presented in the literature for these tasks [4,6,7], there is still need of further research. On one hand, there are several problems associated with modern power systems, such as a massive proliferation of non-linear loads that generate harmonic content and a distributed generation that produces intermittent and variable power [8][9][10][11]. These require the development of both new technologies to reduce their negative impact, such as compensators, active filters, and energy storage systems, among others [9,11,12], and PQ monitoring systems that provide information about the voltage and current waveforms for further processing and analysis 60 Hz, from the original signal.…”
Section: Introductionmentioning
confidence: 99%