1984
DOI: 10.1117/12.7973301
|View full text |Cite
|
Sign up to set email alerts
|

Instantaneous Phase Measuring Interferometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
52
0

Year Published

1990
1990
2015
2015

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 184 publications
(52 citation statements)
references
References 0 publications
0
52
0
Order By: Relevance
“…In addition, in the laboratory circumstance, the measurement precision of laser polarization interferometry is higher than that of laser heterodyne interferometry, and therefore the former has a wide prospect for applications in the high precision measurement. Investigations on the main error sources as well as their mechanisms in the laser polarization interferometer, which help to reduce the measurement nonlinearity and hence improve the measurement precision, are of high necessity.The simultaneous phase-shifting interferometer (SPSI) uses a four-channel simultaneous phase-shifting technique to avoid the direct current (DC) drift influence, which further widens its application range [4,5] . The nonlinear error caused by the imperfect properties of optical elements in SPSI is the key factor that restricts the improvement of measurement precision.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, in the laboratory circumstance, the measurement precision of laser polarization interferometry is higher than that of laser heterodyne interferometry, and therefore the former has a wide prospect for applications in the high precision measurement. Investigations on the main error sources as well as their mechanisms in the laser polarization interferometer, which help to reduce the measurement nonlinearity and hence improve the measurement precision, are of high necessity.The simultaneous phase-shifting interferometer (SPSI) uses a four-channel simultaneous phase-shifting technique to avoid the direct current (DC) drift influence, which further widens its application range [4,5] . The nonlinear error caused by the imperfect properties of optical elements in SPSI is the key factor that restricts the improvement of measurement precision.…”
mentioning
confidence: 99%
“…The simultaneous phase-shifting interferometer (SPSI) uses a four-channel simultaneous phase-shifting technique to avoid the direct current (DC) drift influence, which further widens its application range [4,5] . The nonlinear error caused by the imperfect properties of optical elements in SPSI is the key factor that restricts the improvement of measurement precision.…”
mentioning
confidence: 99%
“…4,5 Dynamic interferometry techniques enable taking all necessary interferometric data simultaneously to determine phase in a single snapshot. [6][7][8] These instruments have been designed with the purpose of measuring phase data in the presence of vibration and air turbulence. 9,10 Interferograms can be captured in "real" time.…”
Section: Dynamic Interferometermentioning
confidence: 99%
“…In order to implement this system under such conditions the optics would have to be redesigned to generate all four phase steps at once. This can be done with a system utilizing four separate TV cameras [6].…”
Section: Conclusion and Future Plansmentioning
confidence: 99%