2017
DOI: 10.1016/j.fusengdes.2017.02.111
|View full text |Cite
|
Sign up to set email alerts
|

Installation of the soft X-ray multi-camera tomography system (XMCTS) in the Wendelstein 7-X stellarator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(23 citation statements)
references
References 8 publications
0
23
0
Order By: Relevance
“…At φ = 15 • a second Doppler reflectometer is also installed. The other two planes have been considered since the distance between them in φ is one fourth of a the machine period, the first of them being the frequently represented triangular plane where other essential diagnostics for impurity transport look at, like the soft-X rays Multi-Camera Tomography System (XMCTS) [48] or the bolometry cameras [49]. The difference between the figures on the left, with labels (a)-(d), and on the right, with labels (e)-(h), is that while the former show the results assuming adiabatic electrons, the latter do it for the cases considering kinetic electrons.…”
Section: Potential Variations In W7-x: Cerc Plasmas and Effect Of Kinmentioning
confidence: 99%
“…At φ = 15 • a second Doppler reflectometer is also installed. The other two planes have been considered since the distance between them in φ is one fourth of a the machine period, the first of them being the frequently represented triangular plane where other essential diagnostics for impurity transport look at, like the soft-X rays Multi-Camera Tomography System (XMCTS) [48] or the bolometry cameras [49]. The difference between the figures on the left, with labels (a)-(d), and on the right, with labels (e)-(h), is that while the former show the results assuming adiabatic electrons, the latter do it for the cases considering kinetic electrons.…”
Section: Potential Variations In W7-x: Cerc Plasmas and Effect Of Kinmentioning
confidence: 99%
“…The SXR tomography diagnostic XMCTS is installed inside the plasma vessel of W7-X [18]. A schematic diagram of its mechanical design and location in the device is shown in figure 1.…”
Section: Methodsmentioning
confidence: 99%
“…The power of this method lies in the fact that, when using GPT, an objective criterion is available to guide the algorithm towards a choice of hyperparameter values that explains the data as good as possible, without requiring a too complex emission profile. The so-called evidence term in Bayes' formula (see equation (18) below) acts as a penalty for small length-scales of the inferred emission profile to limit the space of solutions to those just as complex as allowed for by the uncertainties of the observations (i.e. the measured photodiode signals).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The triple GEM detector was therefore proposed by ENEA in order to have a very performing and flexible device able to provide information, in combination with other diagnostics (e.g. soft X-ray multicamera tomography system [7]), to many physical processes occurring in the plasma, in particular for ambitious experiment like W7-X exploring, for the first time, an unknown territory. The ENEA proposal concerns the installation of a GEM 1D system on W7-X and is currently planned for the machine operation phase 2.0.…”
Section: W7-x Gem Installation Proposalmentioning
confidence: 99%