2014
DOI: 10.1016/j.apradiso.2013.11.056
|View full text |Cite
|
Sign up to set email alerts
|

Installation and performance testing of an XtRa – NaI(Tl) Compton Suppression System at the NED-NTUA

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 5 publications
0
2
0
1
Order By: Relevance
“…Towards that direction, several reports can be found on low-level systems, including Compton Suppression Systems, which have been traditionally used in NAA applications and for monitoring purposes at CTBTO stations. Today such systems are used for the detection of environmental radioactivity (Sima and Osvath, 2013;Sivers et al, 2014;Savva et al, 2014;Fan et al, 2013;Khan et al, 2014). Some innovative applications are also presented, including a state of the art coincidence system consisting of a PIPSBox to detect 131m Xe Conversion Electrons, coupled to a BEGe detector (Cagniant et al, 2014).…”
Section: Current Research In the Field Of Environmental Radioactivitymentioning
confidence: 99%
“…Towards that direction, several reports can be found on low-level systems, including Compton Suppression Systems, which have been traditionally used in NAA applications and for monitoring purposes at CTBTO stations. Today such systems are used for the detection of environmental radioactivity (Sima and Osvath, 2013;Sivers et al, 2014;Savva et al, 2014;Fan et al, 2013;Khan et al, 2014). Some innovative applications are also presented, including a state of the art coincidence system consisting of a PIPSBox to detect 131m Xe Conversion Electrons, coupled to a BEGe detector (Cagniant et al, 2014).…”
Section: Current Research In the Field Of Environmental Radioactivitymentioning
confidence: 99%
“…The gamma-ray spectrometry system used consists of a closed-end coaxial Extended Range (XtRa) Germanium detector, with a 104.5% relative efficiency, housed in an old steel shield and equipped with a Compton Suppression System [14]. For the determination of 7 Be and 210 Pb, the suppressed spectrum is used, since it leads to lower peak area uncertainties.…”
Section: Gamma Spectroscopic Analysismentioning
confidence: 99%
“…Στη δημοσίευση(Savva, et al, 2014), μετά από σχόλιο των κριτών, οι συντελεστές R p παρουσιάζονται με την ονομασία A.S.F.…”
unclassified