2009
DOI: 10.1109/tpwrd.2009.2028534
|View full text |Cite
|
Sign up to set email alerts
|

Inspection of Insulators on High-Voltage Power Transmission Lines

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
20
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 47 publications
(20 citation statements)
references
References 17 publications
0
20
0
Order By: Relevance
“…The various methods, based on laboratory experiments and in-the-field tests, have been proposed to inspect the insulator. In [3], the Hough transform line detection method has been proposed to study the insulator tilt affects using morphological operations. The fault detection accuracy was performed by using feature extraction technique the Gray-level-Co-occurrence matrices (GLCM) form airborne images.…”
Section: B Insulator Monitoring Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The various methods, based on laboratory experiments and in-the-field tests, have been proposed to inspect the insulator. In [3], the Hough transform line detection method has been proposed to study the insulator tilt affects using morphological operations. The fault detection accuracy was performed by using feature extraction technique the Gray-level-Co-occurrence matrices (GLCM) form airborne images.…”
Section: B Insulator Monitoring Methodsmentioning
confidence: 99%
“…A computational electric field approach [7] evaluates the condition of an insulator and detect internal defects not accurate for internal cracks Infrared and ultraviolet imaging technique [8] detects the temperature variance caused by internal cracks high cost, limited number of conditional defects; sensitive to the environment Harmonic retrieval method [3] remote inspection based on analysis of the low frequency even-order harmonic of the basic power line transmission frequency (60 Hz), can be used in the high voltage power lines high cot, time consuming Watershed algorithm technique [9] detection of the dirt area in the images of the insulator surface sensitive to small changes, oversegmentation phenomena Hough transform line detection method [3] insulator tilt correction based on Hough transform technique; stable and robust to noises in images error in tilt angle calculation Insulator Hydrophobicity inspection [5] the polynomial classifier performs high classification accuracy applicable for a small class number due to its computation complexity.…”
Section: Advantages Limitationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Corona discharges can cause insulation aging, cracking, and insulation accidents, which affect the safe operation of electrical equipment [1][2][3][4]. Therefore, timely detection of the location and intensity of corona discharges is important for the secure operation of power systems.…”
Section: Introductionmentioning
confidence: 99%
“…Inspection with an infrared and ultraviolet camera is a direct method to observe the pollution condition of insulator [3]. Unfortunately, the cost and reliability of the cameras limit the system application in harsh environment, such as the extreme cold or hot, high humidity, icing, lightning and strong electromagnetic interference.…”
Section: Introductionmentioning
confidence: 99%