1999
DOI: 10.1144/gsl.sp.1999.159.01.10
|View full text |Cite
|
Sign up to set email alerts
|

Insights from simultaneous acoustic and resistivity imaging

Abstract: We describe a method of thin-bed petrophysical analysis that exploits the availability of both acoustic and resistivity images of the same rock. In developing our method we have gained a number of insights into the contrasting response of these images to rock properties, which may be of general interest to the imaging community. The case-study we present is from a thin-bedded, deep-water siliciclastic depositional environment. The resistivity image was used to increase the resolution of a conventional resistiv… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1999
1999
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…It is noted that the two types of images are complimentary. Hayman et al (1994) and Hansen & Parkinson (1999) show how interpretation can indeed be enhanced when both types of images are available.…”
Section: Discussion and Summarymentioning
confidence: 99%
See 1 more Smart Citation
“…It is noted that the two types of images are complimentary. Hayman et al (1994) and Hansen & Parkinson (1999) show how interpretation can indeed be enhanced when both types of images are available.…”
Section: Discussion and Summarymentioning
confidence: 99%
“…It would be safer in such cases to compare dips from microresistivity devices with cores or other measurements. Hansen & Parkinson (1999) report a depth of investigation of 5-7 cm in a study comparing images from microresistivity and ultrasonic devices. Trouiller et al (1989) mention that in thick homogeneous or finely laminated beds, the depth of investigation of a button is similar to that of a shallow laterolog, which is roughly 25 cm.…”
Section: B U T T O N Sensor R E S P O N S Ementioning
confidence: 99%
“…The difficulty is in obtaining a quantitative resistivity measurement at a similar scale to the resolution of the imaging device. In thickly bedded, homogeneous sequences the constraints are such that calibration may be feasible (Hansen & Parkinson 1999). Unfortunately, in thinly bedded or heterogeneous zones the devices sample different volumes and thus comparison and calibration is less reliable.…”
Section: Imagesmentioning
confidence: 99%