INRIM primary standard for microgas-flow measurements with reference to atmospheric pressure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 12 publications
(11 reference statements)
0
6
0
Order By: Relevance
“…This method is used for its directness in many laboratories, for example Istituto Nazionale di Ricerca Metrologica-INRIM [12], Laboratoire national de métrologie et d'essais-LNE [13,14], Physikalisch-Technische Bundesanstalt-PTB [15], Shanghai Institute of Measurement and Testing Technology-SIMT [16] and also by the company Inficon [17]. All of these organizations use it in the constant-pressure and variablevolume mode but SIMT also uses the constant-volume and variable-pressure mode.…”
Section: Accumulation Methodsmentioning
confidence: 99%
“…This method is used for its directness in many laboratories, for example Istituto Nazionale di Ricerca Metrologica-INRIM [12], Laboratoire national de métrologie et d'essais-LNE [13,14], Physikalisch-Technische Bundesanstalt-PTB [15], Shanghai Institute of Measurement and Testing Technology-SIMT [16] and also by the company Inficon [17]. All of these organizations use it in the constant-pressure and variablevolume mode but SIMT also uses the constant-volume and variable-pressure mode.…”
Section: Accumulation Methodsmentioning
confidence: 99%
“…In leak metrology, the "state-of-the-art" instrument to achieve such measurements is the constant-pressure flowmeter [1], [2]. While the equation for the throughput can be written simply as:…”
Section: Introductionmentioning
confidence: 99%
“…𝑝 0 being the constant pressure set in the instrument, the associated volume variation device makes this instrument somewhat complicated to build [1], [2].…”
Section: Introductionmentioning
confidence: 99%
“…Therefore it was decided to realize leak elements with well-defined geometry. The artefacts have been characterized geometrically and the flow rate measured with primary standards [4][5][6][7][8][9] against vacuum and atmospheric pressure for different gases. In the first part of the paper, the description of the realization and geometrical characterization is reported.…”
Section: Introductionmentioning
confidence: 99%