Input Voltage Feedforward Active Damping-Based Input Current Harmonic Suppression Method for Totem-Pole Bridgeless PFC Converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 32 publications
0
3
0
Order By: Relevance
“…This topology achieves this by employing a totem-pole configuration of power switches (see Figure 9). This configuration allows for bidirectional power flow and simultaneously reduces the voltage stress placed on the switches, further enhancing efficiency [75][76][77]. Various power semiconductor devices can be utilized to implement the Bridgeless Totem-Pole PFC topology, including silicon MOSFETs, silicon carbide MOSFETs, and gal-lium nitride (GaN) devices.…”
Section: Bridgeless Totem-pole Pfcmentioning
confidence: 99%
“…This topology achieves this by employing a totem-pole configuration of power switches (see Figure 9). This configuration allows for bidirectional power flow and simultaneously reduces the voltage stress placed on the switches, further enhancing efficiency [75][76][77]. Various power semiconductor devices can be utilized to implement the Bridgeless Totem-Pole PFC topology, including silicon MOSFETs, silicon carbide MOSFETs, and gal-lium nitride (GaN) devices.…”
Section: Bridgeless Totem-pole Pfcmentioning
confidence: 99%
“…A thorough analysis of the Bode diagram and zero-pole diagram is conducted for three virtual impedances to ultimately select the virtual resistance as the optimal type of virtual impedance. Reference [ 19 ] proposes a Grid-side Current Harmonic Suppression (GCHS) method based on input voltage feedforward active damping. By extracting harmonic information and combining it with current setting and modulation voltage information, the suppression of current harmonics under different loads can be achieved.…”
Section: Introductionmentioning
confidence: 99%
“…However, when a distorted PCC voltage is applied to the input port of PFC converter, the distorted input current will be produced and it may make the PFC converter work in an uncontrollable state. To avoid this state, in reference [24], the PFC converters with excellent performance are proposed to ensure that non-linear load will not cause harmonic interference to itself. For avoiding the harmonic interference of grid, a virtual harmonic impedance is built in the feed-forward control loop of the PFC converter and leaves a high resistance at the specific harmonic frequency.…”
Section: Introductionmentioning