2014
DOI: 10.1042/bj20140237
|View full text |Cite
|
Sign up to set email alerts
|

Inositol phosphates induce DAPI fluorescence shift

Abstract: The polymer inorganic polyP (polyphosphate) and inositol phosphates, such as IP6 (inositol hexakisphosphate; also known as phytic acid), share many biophysical features. These similarities must be attributed to the phosphate groups present in these molecules. Given the ability of polyP to modify the excitation-emission spectra of DAPI we decided to investigate whether inositol phosphates possess the same property. We discovered that DAPI-IP6 complexes emit at approximately 550 nm when excited with light of wav… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
28
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8
2

Relationship

4
6

Authors

Journals

citations
Cited by 30 publications
(32 citation statements)
references
References 39 publications
0
28
0
Order By: Relevance
“…Because phytic acid can also interact and fluoresce with DAPI at the same wavelengths as polyphosphate (24), conditioned medium was treated with the phytic acid-degrading enzymes phytase and DDP1 (25,26). Phytase or DDP1 treatments had no effect on DAPI fluorescence of conditioned medium or on the activity of the stationary phase factor (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Because phytic acid can also interact and fluoresce with DAPI at the same wavelengths as polyphosphate (24), conditioned medium was treated with the phytic acid-degrading enzymes phytase and DDP1 (25,26). Phytase or DDP1 treatments had no effect on DAPI fluorescence of conditioned medium or on the activity of the stationary phase factor (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…This discrepancy is likely due to the different assays used to quantify polyP: namely the direct visualisation of polyP on gel, or by measuring polyPinduced DAPI (4',6-Diamidino-2-Phenylindole) red fluorescence shift [74]. The latter assay has pitfalls as other phosphate-rich molecules, such as IPs [75] and amorphous calciumphosphate [76], induce the same type of fluorescence. Thus, unlike in yeast, the direct control of polyP synthesis by PP-IPs is not seen in D. discoideum.…”
Section: Inorganic Polyphosphate As a Eukaryote Phosphate Buffermentioning
confidence: 96%
“…Several polyP detection methods lack specificity (23). Furthermore quantification of polyP using traditional biochemical assays, such as the PPK assay (8) or measurement of free phosphate (Pi) after polyP hydrolysis, are greatly impaired by the inability to extract polyP without copurifying other phosphate rich molecules (see below).…”
Section: Discoideum Possesses Polypmentioning
confidence: 99%