2016
DOI: 10.1002/jssc.201600712
|View full text |Cite
|
Sign up to set email alerts
|

Inorganic–organic hybrid coating material for the online in‐tube solid‐phase microextraction of monohydroxy polycyclic aromatic hydrocarbons in urine

Abstract: An inorganic-organic hybrid nanocomposite (zinc oxide/polypyrrole) that represents a novel kind of coating for in-tube solid-phase microextraction is reported. The composite coating was prepared by a facile electrochemical polymerization strategy on the inner surface of a stainless-steel tube. Based on the coated tube, a novel online in-tube solid-phase microextraction with liquid chromatography and mass spectrometry method was developed and applied for the extraction of three monohydroxy polycyclic aromatic h… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
11
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(12 citation statements)
references
References 38 publications
1
11
0
Order By: Relevance
“…The intra‐ and inter‐day precisions (RSD) ranged from 2.4 to 8.7% and 2.9 to 9.9%, respectively. As overviewed in Table , LODs (0.02–0.1 ng/mL) and recoveries (77.5–97.1%) for the target compounds are comparable with the other reported results obtained by LC‐MS/MS for the similar multi‐analyte determination of OH‐PAHs in urine samples .…”
Section: Resultssupporting
confidence: 88%
“…The intra‐ and inter‐day precisions (RSD) ranged from 2.4 to 8.7% and 2.9 to 9.9%, respectively. As overviewed in Table , LODs (0.02–0.1 ng/mL) and recoveries (77.5–97.1%) for the target compounds are comparable with the other reported results obtained by LC‐MS/MS for the similar multi‐analyte determination of OH‐PAHs in urine samples .…”
Section: Resultssupporting
confidence: 88%
“…In another study by Naccarato et al, the Generally speaking, urine is undoubtedly the preferred matrix among the analyzed biological fluids because of its greater biological half-life and its less invasive sampling. This trend is confirmed in the last lustrum since most of the published works on this topic have been directed, as well as to the assay of markers of several pathological conditions [210][211][212], toward the determination of several contaminants in urine samples [14,74,83,[213][214][215][216][217][218][219]. Few studies focused on hair [220][221][222], three papers were published about analysis in blood/serum [29,223,224], and one regarding meconium [225].…”
Section: The Final Endpoint: Bio-clinical Matricesmentioning
confidence: 95%
“…The satisfactory results achieved in terms of the lifetime of coatings and validation parameters created not only new alternatives for polycyclic aromatic hydrocarbon exposure assessment but also opened new perspectives for the application of direct immersion solid-phase microextraction to the analysis of bio-clinical matrices. As for food analysis, various coatings were proposed for the analysis of urine, such as C 18 /PAN [213], layered double hydroxide/graphene (LDH-G) [218], inorganic-organic hybrid nanocomposite [219], and cross-linked PIL [83] for the determination of hydroxylated PAHs as metabolites of PAHs [213,219], organochlorine pesticides [218], and endocrine-disrupting chemicals [83]. In the study proposed by Yang et al [213], an improved low-cost direct SPME-MS technique with glass capillary was further developed for the determination of five typical OH-PAHs in urine samples using a C18-SPME fiber, which then was inserted into a prefilled glass-capillary with spray solvent to generate ions for MS analysis.…”
Section: The Final Endpoint: Bio-clinical Matricesmentioning
confidence: 99%
“…Other materials that have been employed as coating materials for capillary columns include β-cyclodextrin [117], titania (TiO 2 ) [118], polydopamine/dialdehyde starch/chitosan composite [112], Fe 3 O 4 /SiO 2 /layered double (Cu-Cr) hydroxide nanoparticles [113], Cu-Cr-Al ternary layered double hydroxide/polythiophene coating [119], polypyrrole [120][121][122][123][124][125][126][127][128][129], sol-gel materials [130], and Fe 3 O 4 /SiO 2 [131].…”
Section: Other Materialsmentioning
confidence: 99%
“…A hybrid inorganic-organic zinc oxide/polypyrrole coating material has been also synthesized and evaluated for the online in-tube SPME of monohydroxy polycyclic aromatic hydrocarbons in urine. The hybrid sorbent combined the large surface area of zinc oxide nanorods and the porous structure of polypyrrole to provide a stable coating with a long lifespan [129].…”
Section: Other Materialsmentioning
confidence: 99%