2018
DOI: 10.1061/(asce)cc.1943-5614.0000869
|View full text |Cite
|
Sign up to set email alerts
|

Innovative Structural and Energy Retrofitting System for Masonry Walls Using Textile Reinforced Mortars Combined with Thermal Insulation: In-Plane Mechanical Behavior

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
2
1

Relationship

2
7

Authors

Journals

citations
Cited by 37 publications
(11 citation statements)
references
References 25 publications
0
11
0
Order By: Relevance
“…All the above is investigated experimentally, analytically and numerically in the present study, for the case of masonry walls subjected to out-of-plane cyclic loading. More details on the experimental part for the case of out-of-plane, and also related to in-plane loading are given in [5,6]. The experimental results are found in good agreement with analytical modeling as well as finite element modeling; both modeling approaches may be used in future studies to perform detailed parametric analyses.…”
Section: Introductionmentioning
confidence: 53%
“…All the above is investigated experimentally, analytically and numerically in the present study, for the case of masonry walls subjected to out-of-plane cyclic loading. More details on the experimental part for the case of out-of-plane, and also related to in-plane loading are given in [5,6]. The experimental results are found in good agreement with analytical modeling as well as finite element modeling; both modeling approaches may be used in future studies to perform detailed parametric analyses.…”
Section: Introductionmentioning
confidence: 53%
“…Finally, the use of TRM jacketing for strengthening of masonry infills has been combined with thermal insulation materials for providing concurrent seismic and energy retrofitting. The concept of combined seismic and energy retrofitting with advanced materials was proposed for the first time and investigated experimentally for the case of masonry subjected to out-of-plane (Triantafillou et al 2017) and in-plane (Triantafillou et al 2018) loading. These studies introduced for the first time the combination of TRM with standard or even highly fire-resistant thermal insulation materials.…”
Section: Seismic Retrofitting Of Masonry-infilled Rc Framesmentioning
confidence: 99%
“…Textile Reinforced Mortar (TRM), also termed Fabric Reinforced Cementitious Matrix (FRCM) composites (Triantafillou, 2016) has been recently applied coupled with insulation panels for seismic and energy retrofit purposes (Triantafillou et al, 2018;Gkournelos et al, 2020). The first experimental results demonstrated that this combined solution increases the seismic safety level of the retrofitted construction, even considering the application on one side only and with different dispositions of the TRM system with respect to the insulation layers (see Figure 10).…”
Section: Textile Reinforced Mortarmentioning
confidence: 99%
“…Moreover, the curing process of geopolymer may produce a considerable quantity of salts if the chemical constituents are not carefully evaluated (Miranda et al, 2017). Such salts have a damaging impact not only on the existing substrate, especially for historic FIGURE 10 Scheme of the TRM structural and energy retrofitting solution: (A) masonry wall (Triantafillou et al, 2018); (B) RC frame (Pohoryles et al, 2020).…”
Section: Geopolymersmentioning
confidence: 99%