2019
DOI: 10.1016/j.microc.2019.104225
|View full text |Cite
|
Sign up to set email alerts
|

Inline simultaneous quantitation of tobacco chemical composition by infrared hyperspectral image associated with chemometrics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
22
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 19 publications
(22 citation statements)
references
References 26 publications
0
22
0
Order By: Relevance
“…Figure 4 shows the correlation between the measured values (y measured) of the reference method and the results predicted (y predicted) by the PLS model (nitrate and ammonia) and siPLS (total alkaloids and reducing sugars). It was possible to obtain a good correlation for total alkaloids and reducing sugars models, and the values obtained for F I G U R E 4 Correlation between the measured values (y measured) of the reference method and the results predicted (y predicted) by the partial least-squares (PLS) model (nitrate and ammonia) and synergy interval PLS (siPLS) (total alkaloids and reducing sugars) coefficients (R 2 CV and R 2 p ) were higher than 0.9, which means an appropriate goodness-of-fit and fair precision. 4,39 For the other parameters, the models that were developed did not attain the recommended coefficient minimum values, obtained R 2 CV = 0.32 and R 2 CV = 0.77 for nitrate and ammonia, respectively.…”
Section: F I G U R Ementioning
confidence: 93%
See 4 more Smart Citations
“…Figure 4 shows the correlation between the measured values (y measured) of the reference method and the results predicted (y predicted) by the PLS model (nitrate and ammonia) and siPLS (total alkaloids and reducing sugars). It was possible to obtain a good correlation for total alkaloids and reducing sugars models, and the values obtained for F I G U R E 4 Correlation between the measured values (y measured) of the reference method and the results predicted (y predicted) by the partial least-squares (PLS) model (nitrate and ammonia) and synergy interval PLS (siPLS) (total alkaloids and reducing sugars) coefficients (R 2 CV and R 2 p ) were higher than 0.9, which means an appropriate goodness-of-fit and fair precision. 4,39 For the other parameters, the models that were developed did not attain the recommended coefficient minimum values, obtained R 2 CV = 0.32 and R 2 CV = 0.77 for nitrate and ammonia, respectively.…”
Section: F I G U R Ementioning
confidence: 93%
“…For the PLS models, the spectra that range between 1,000 and 2,300 nm were used. Four datasets were created 1 for total alkaloids, 2 reducing sugars, 3 nitrate, and 4 ammonia with 245 samples. Each dataset was split into two new datasets (calibration and prediction) using the Kennard‐Stone algorithm 25 ; files were split into two thirds of the data for calibration and one third for prediction.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations