Initial implementation of external accumulation liquid chromatography/electrospray ionization Fourier transform ion cyclotron resonance with automated gain control

Abstract: Capillary liquid chromatography (LC) separation coupled with external accumulation Fourier transform ion cyclotron resonance (FTICR) mass spectrometry has recently been demonstrated to have significant potential for proteomics research. Accumulation of an excessive space charge external to the FTICR cell ion trap has been shown to result in increased mass measurement error, undesirable ion discrimination and/or fragmentation, potentially causing misrepresentation or incorrect assignments of lower abundance pep… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
29
0

Year Published

2003
2003
2020
2020

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 34 publications
(29 citation statements)
references
References 35 publications
0
29
0
Order By: Relevance
“…3c). In practice, saturation is more often observed for quadrupole TOF instruments than ion traps because these latter devices can control the number of ions before detection [70]. In any case, the relatively recent introduction of high-resolution/ high mass accuracy mass spectrometers in proteomics has interfering signals with signal to noise ratios too low for reliable quantification.…”
Section: Lc-ms/ms Analysis Of Stable Isotope Labeled Peptidesmentioning
confidence: 99%
“…3c). In practice, saturation is more often observed for quadrupole TOF instruments than ion traps because these latter devices can control the number of ions before detection [70]. In any case, the relatively recent introduction of high-resolution/ high mass accuracy mass spectrometers in proteomics has interfering signals with signal to noise ratios too low for reliable quantification.…”
Section: Lc-ms/ms Analysis Of Stable Isotope Labeled Peptidesmentioning
confidence: 99%
“…This capability for data-dependent adjustment of ion accumulation time during an LC separation maintains ion populations in the FTICR cell so as not to exceed a level that causes excessive space charge effects. AGC also helps eliminate m/z discrimination in the external ion trap and improves the MMA and/or the dynamic range of measurements (Belov, et al, 2003a, Belov, et al, 2003b. Recently, Thermo Electron Corporation has incorporated this AGC approach into their LTQ FT™ mass spectrometer.…”
Section: Increased Mass Measurement Accuracy (Mma)mentioning
confidence: 99%
“…For LC, mass spectrometry, Belov et al (2003) described a feedback mechanism that automatically adjusts the ion injection time to prevent space charge problems in the linear and FTMS traps. A pre-scan mass spectrum (similar to DREAMS) is obtained and based on the total ion signal chromatogram (the sum of the ion intensities for a range of m/z) the ion injection time is adjusted to allow similar numbers of charges to be accumulated in the linear trap.…”
mentioning
confidence: 99%