1993
DOI: 10.1016/0002-9149(93)90811-p
|View full text |Cite
|
Sign up to set email alerts
|

Initial experience and potential applications of multiplane transesophageal echocardiography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
3
0
1

Year Published

1994
1994
2021
2021

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 26 publications
(5 citation statements)
references
References 9 publications
1
3
0
1
Order By: Relevance
“…These data are in accordance with reports on multiplane TEE which showed that structures with a complex spatial orientation such as aortic valve, ascending aorta, aortic arch, and coronary arteries are more easily and completely assessed with multiplane TEE [7,[13][14][15][16][17][18] . Thus, multiplane TEE appears to be an ideal method to give detailed anatomical information about the morphology of a dissection, and can also show the consequences and complications of proximal extension.…”
Section: Discussionsupporting
confidence: 92%
“…These data are in accordance with reports on multiplane TEE which showed that structures with a complex spatial orientation such as aortic valve, ascending aorta, aortic arch, and coronary arteries are more easily and completely assessed with multiplane TEE [7,[13][14][15][16][17][18] . Thus, multiplane TEE appears to be an ideal method to give detailed anatomical information about the morphology of a dissection, and can also show the consequences and complications of proximal extension.…”
Section: Discussionsupporting
confidence: 92%
“…More recently, multiplane TEE probes have become available, allowing stepwise study of an area of interest by fine mechanical or electronic rotation of the scanning plane through 180 degrees. [16][17][18][19][20][21][22] …”
mentioning
confidence: 99%
“…Die Kontraktion des Myokards, der Füllungszustand der Kammern und die Klappenfunktion werden damit einer kontinuierlichen Beobachtung zugänglich und können mit zusätzlichen Verfahren, etwa der dopplerechokardiographischen Klappenuntersuchung, einer ergänzenden Beurteilung unterzogen werden. in deren Schallkopf die angeordneten Wandler durch einen miniaturisierten Elektromotor bis zu 180 Grad um ihren Mittelpunkt gedreht werden können, was die Einstellung von beliebigvielen Zwischenebenen ermöglicht (29). Der Schallkopf dieser sogenannten ,,omniplanen" Sonde ist im Vergleich zur monoplanen Sonde nur wenig gröger und arbeitet wahlweise mit Frequenzen von 3,75 oder 5 MHz.…”
Section: Zweidimensionales Verfahrenunclassified