2015
DOI: 10.1053/j.jvca.2014.09.016
|View full text |Cite
|
Sign up to set email alerts
|

Initial Clinical Experience With a Miniaturized Transesophageal Echocardiography Probe in a Cardiac Intensive Care Unit

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
15
0
1

Year Published

2015
2015
2019
2019

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 21 publications
(17 citation statements)
references
References 32 publications
1
15
0
1
Order By: Relevance
“…Interestingly, hTEE monitoring detected new and/or clinically unexpected right ventricular (RV) dysfunction [19,33,34] in approximately one-third of the patients, comparable to a previous study [14]. Fletcher et al [19] also detected even more new right ventricular failure (67.6 %) in ventilated patients with severe cardiogenic shock requiring hemodynamic support using hTEE.…”
Section: Discussionsupporting
confidence: 74%
See 2 more Smart Citations
“…Interestingly, hTEE monitoring detected new and/or clinically unexpected right ventricular (RV) dysfunction [19,33,34] in approximately one-third of the patients, comparable to a previous study [14]. Fletcher et al [19] also detected even more new right ventricular failure (67.6 %) in ventilated patients with severe cardiogenic shock requiring hemodynamic support using hTEE.…”
Section: Discussionsupporting
confidence: 74%
“…Fletcher et al [19] also detected even more new right ventricular failure (67.6 %) in ventilated patients with severe cardiogenic shock requiring hemodynamic support using hTEE. Also, one pericardial tamponade by monoplane hTEE was detected in a very early postoperative time frame with consequent re-operation [35][36][37][38][39].…”
Section: Discussionmentioning
confidence: 92%
See 1 more Smart Citation
“…Simplified insertion and improved tolerance are among the potential benefits for hemodynamically unstable patients requiring mechanical ventilation [17, 18]. In the intensive care unit setting, hTEE provides supplementary information to invasive monitoring [19] and displays good interrater reliability when performed by nonexperienced operators [20]. Thus, hTEE theoretically provides a safer, faster, and more user-friendly assessment of hemodynamic status compared to TTE and continuous TEE.…”
Section: Discussionmentioning
confidence: 99%
“…In our case, close monitoring of VA-ECMO support with hTEE allowed us to better characterize a complex state of shock (cardiogenic and vasodilatory) [19]. Hence, we have a more appropriate initial resuscitation in the early phase of our patient's care.…”
Section: Discussionmentioning
confidence: 99%