2017
DOI: 10.1111/ner.12602
|View full text |Cite
|
Sign up to set email alerts
|

Inhibitory Effects and Mechanisms of Electroacupuncture via Chronically Implanted Electrodes on Stress-Induced Gastric Hypersensitivity in Rats With Neonatal Treatment of Iodoacetamide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
33
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 36 publications
(34 citation statements)
references
References 43 publications
0
33
0
1
Order By: Relevance
“…A watch‐size digital stimulator (SNM‐FDC01, Ningbo Maida Medical Device, Inc., Ningbo, China) was used to deliver trains of pulses. The stimulation parameters for ST36 stimulator were set at 2 sec on and 3 sec off, pulse width of 0.5 msec, pulse frequency of 25 Hz, and amplitude of 2–10 mA (at the maximum level tolerated by the subject) based on previous studies ; for PC6, stimulator was set at 0.1 sec on and 0.4 sec off, pulse width of 0.5 msec, pulse frequency of 100 Hz, and amplitude of 2–10 mA, which were shown to improve nausea and vomiting, and visceral pain . The bilateral stimulation TN treatment was given for half hour, twice daily (once on the day of surgery), lasting for 4 days.…”
Section: Methodsmentioning
confidence: 99%
“…A watch‐size digital stimulator (SNM‐FDC01, Ningbo Maida Medical Device, Inc., Ningbo, China) was used to deliver trains of pulses. The stimulation parameters for ST36 stimulator were set at 2 sec on and 3 sec off, pulse width of 0.5 msec, pulse frequency of 25 Hz, and amplitude of 2–10 mA (at the maximum level tolerated by the subject) based on previous studies ; for PC6, stimulator was set at 0.1 sec on and 0.4 sec off, pulse width of 0.5 msec, pulse frequency of 100 Hz, and amplitude of 2–10 mA, which were shown to improve nausea and vomiting, and visceral pain . The bilateral stimulation TN treatment was given for half hour, twice daily (once on the day of surgery), lasting for 4 days.…”
Section: Methodsmentioning
confidence: 99%
“…For example, alternative uses of 2 and 100 Hz stimulation are commonly used for treating pain due to different effects of low‐frequency and high‐frequency stimulations on enkephalin and endorphin . A combinational use of 2 and 100 Hz stimulation has been shown to be effective in reducing chemotherapy‐induced nausea and vomiting, and treating visceral pain . Low‐frequency stimulation is commonly used in cardiac applications .…”
Section: Types Of Electroacupuncture and Its Deliverymentioning
confidence: 99%
“…In addition to its prokinetic effects, EA is also known to have an analgesic effect. A few major mechanisms involved in the analgesic effect of EA on visceral pain or hypersensitivity have been reported: sensory afferent mechanisms involving dorsal root ganglions and opioid mechanisms and vagally mediated mechanisms . It should also be noted that EA stimulation parameters for treating visceral pain may be distinctly different from those used for treating gut dysmotility …”
Section: Mechanisms Of Electroacupuncturementioning
confidence: 99%
See 2 more Smart Citations